Conditional grantDecided 18 June 2025Carlow County Council

2460302: Development that would extend the existing metal recycling facility (permitted under Reg. Ref. 09/308) at the site of Flynn's Metal Recycling Ltd., Tullow Road, Bennekerry, Co. Carlow. The proposed development consists of: • The retention of an extended concrete yard, and a hardcore surface yard and its proposed upgrade to a concrete surface, to integrate with the use and operation of the existing metal recycling facility. • The retention of boundary treatments including palisade fence on retaining wall. • The retention of a weigh bridge and ancillary cabins. • The demolition of existing storage and ancillary buildings. • The erection of a new single storey pitched roof workshop and materials storage building, that will include a management office and staff welfare facilities, with solar panels at roof level. • The erection of portable block walls to form external bays to store segregated metals. • The creation of a new site access from the R725 and a gated entrance and the closure of the existing site entrance. • Site drainage works, boundary treatments, lighting, landscaping, parking areas for cars and trucks, signage and all other site development works above and below ground. • This will facilitate the increase in intake of waste materials to 17,500 Tonnes per annum

Flynn's Metal Recycling Ltd, Tullow Road, Bennekerry
DecisionConditional grant
Decided18 June 2025
Application typeRETENTION
Source documents6

Site

What is on file

0refusal reasons25conditions8nearby records

Decision details

Core application dates and identifiers from the public planning record.

Planning analysis

Refusal reasons and planning conditions extracted from the public decision file.

Refusal reasons

No refusal reason

No refusal reason is on record for this application yet.

Conditions

  • , Surface water diverted to 2 on-site soakaways (660m³ and 300m³) within site boundary.Wastewater Drainage
  • , Only clean/uncontaminated surface water to enter soakaways.Wastewater Drainage
  • , Soakaways designed per BRE Digest 365.Wastewater Drainage
  • , No surface water dispersed onto public roadway.Wastewater Drainage
  • , Hydrocarbon interceptor installed per submitted drawings.Wastewater Drainage
  • , Regular surface water quality sampling from interceptor; records kept for inspection.Wastewater Drainage
  • , Percolation piping min 36m (4x9m); no single pipe >10m.Wastewater Drainage
  • , Vents at pipe ends; max 6 distribution pipes from single box; pipes originate from box.Wastewater Drainage
  • , Pipe seals on distribution pipes; liquid levelling device on percolation pipes.Wastewater Drainage
  • , Activated carbon filters on vent pipes; replenished bi-annually.Wastewater Drainage
  • , DWWT system designed/built/maintained per EPA Code of Practice (PE ≤ 10) 2021.Wastewater Drainage
  • , Certificate of Compliance + as-constructed drawings submitted within 6 months of completion.Wastewater Drainage

Source documents

Original council portal records and source PDFs where available.

Nearby precedent