GrantedDecided 01 October 2025Carlow County Council

Ballytarsna, Nurney, Co. Carlow

Planning application 2560174
DecisionConditional grant
Decided01 October 2025
Application typePERMISSION
Source documents6

Site

What is on file

0refusal reasons15conditions8nearby records

Proposed development

Application description published by Carlow County Council.
The construction of a Single Storey Dwelling, wastewater treatment system, a bored well, splayed entrance and all associated site development works

Application and appeal history

Structured appeal stages, outcomes and source documents currently tied to this application.

No indexed appeal history

No structured appeal case is tied to this application. This means no appeal is indexed, not that an appeal is impossible.

Decision details

Core application dates and identifiers from the public planning record.

Planning analysis

Refusal reasons and planning conditions extracted from the public decision file.

Refusal reasons

No refusal reason on record

No refusal reason is on record for this application yet.

Conditions

  • 1Development to be carried out in accordance with plans received 17/06/2025, amended by FI received 08/09/2025.Compliance
  • 2Permission authorises only the development described in public notices and application particulars.Compliance
  • 3Dwelling to be first occupied as permanent residence by applicants and immediate family for 7 years. Section 47 agreement required prior to commencement. Written confirmation of first occupation within 2 months.Occupancy
  • 4External finishes per drawing J1008-PL01-001A. Natural stone only. No white uPVC for windows, doors, or rainwater goods.Design Materials
  • 5Landscaping per 'Proposed Landscaping Plan' (08/09/2025). Native species. Hedgerow along realigned boundary to have 4-5 years growth. Planting completed within first season following construction.Landscaping Boundary
  • 6Certificate of Compliance for on-site wastewater system and percolation area prior to occupation, including site-specific 'as-constructed' drawings. Septic tank tested per I.S. EN 12566. Vents at percolation pipe ends. Max 6 distribution pipes from single box. Pipes originate from distribution box. Pipe seals and liquid levelling devices required. No surface water infiltration. Domestic grease trap installed.Wastewater Drainage
  • 7Clean surface water diverted to soakaways within site boundary per BRE Digest 365. No dispersion onto public roadway.Water Services
  • 8Entrance and sight distances per Site Layout Plan JI008-PL02-001. Areas forward of sight splays grassed. Lines of sight established prior to construction. Road opening licence per 2017 Guidelines required.Traffic Access
  • 9Set back front hedgerow by 2m and provide passing bay.Traffic Access
  • 10Public water/wastewater connection agreement with Uisce Eireann signed prior to commencement. Compliance with CDS Technical Documentation.Water Services
  • 11Service poles relocated prior to construction. All ESB/telephone cables located underground unless otherwise agreed.Other
  • 12Off-carriageway parking for all development traffic. No parking on public road. Prevent muck/dirt on road. Site kept neat and litter-free. Noise/dust emissions controlled.Construction Management

Planning a project near Ballytarsna, Nurney, Co. Carlow?

Get a site risk brief with the local decision pattern and up to 80 detailed nearby comparables (40 refusals and 40 grants), including extracted reasons and source links. €29 incl. VAT, PDF by email.

Source documents

Original council portal records and source PDFs where available.

Nearby precedent

Similar nearby applications linked to this planning decision.