RefusedDecided 02 October 2025Kildare County Council

Ballyvass, Castledermot, Co. Kildare

Planning application 2560920
DecisionRefused
Decided02 October 2025
Application typePERMISSION
Source documents1

Site

What is on file

0refusal reasons0conditions8nearby records

Proposed development

Application description published by Kildare County Council.
For the construction of an anaerobic digestion facility to produce renewable biomethane, CO2 (which will be captured), and a bio-based fertiliser from organic material. The total gross floor area of the proposed development (including internal plant areas and ancillary structures) will be c. 6,007 sq.m. The development will consist of the following: Construction of 2 no. primary digesters (with an overall height of c. 9.1m), a digestate storage tank (with a height of c. 11.3m), a pump house (with a gross floor area (GFA) of c. 362 sq.m), 2 no. post digester tanks (with an overall height of c. 9.1m), and a safety flare (c. 11.3m in height), located in the southeastern section of the site. Construction of 2 no. prepits (c. 4.3m in height), a pasteurisation buffer tank (c. 4.3m in height), and a pasteurisation unit (with a maximum height of c. 4.2m), located to the west of the primary digesters, within the southern section of the site. Construction of digestate treatment and feedstock reception building and odour abatement system (with a GFA of c. 2,797 sq.m and a height of c. 12.1m and c. 16.2m to top of odour abatement stack) located within the southwestern section of the site. Construction of roofed silage clamps (with a GFA of 2,424 sq.m and a height of c. 8.7m) and a fuel storage tank (c. 2m in height), located within the western section of the site. Construction of a combined heat and power (CHP) unit (with a GFA of c. 39 sq.m and a height of c. 2.6m and c. 5.6m to top of flue), a biogas boiler (c. 2.6m in height and c. 5.6m in height to top of flue), a backup boiler (c. 2.6m in height), located within the northern section of the site. Construction of a gas treatment unit (c. 4.2m in height), a grid injection unit (with a GFA of c. 22 sq.m and a height of c. 2.8m), and a CO2 liquefactor (with an overall height of c. 10.7m to top of storage vessels) a propane tank compound accommodating 2 no. propane tanks (c. 1.6m in height), and an ESB substation (with a GFA of c. 24 sq.m and a height of c. 3.4m), located within the northern section of the site. Construction of a two storey ancillary administration building (with a GFA of c. 327 sq.m and a height of c. 11m) within the northern section of the site, adjacent to the site entrance. Alterations to the adjacent local road and site access road, including junction improvement and widening and site entrance and access arrangements. Associated and ancillary works including parking (9 no. standard, 2 no. EV and

Decision details

Core application dates and identifiers from the public planning record.

Planning analysis

Refusal reasons and planning conditions extracted from the public decision file.

Refusal reasons

Refusal reasons not machine-readable

Documents are indexed. Reason extraction for Kildare has not started yet.

Conditions

No conditions

No conditions are on record for this application yet.

Planning a project near Ballyvass, Castledermot, Co. Kildare?

Get a site risk brief with the local decision pattern and up to 80 detailed nearby comparables (40 refusals and 40 grants), including extracted reasons and source links. €49 incl. VAT, PDF by email.

Source documents

Original council portal records and source PDFs where available.

Nearby precedent

Similar nearby applications linked to this planning decision.
Get up to 80 detailed nearby comparables in a site risk brief →