Free preview / €49 incl. VAT full PDF

Planning precedent report

Search a place or planning reference, choose the development type, then preview the report before generating the full PDF.
See sample PDF
Opens secure checkout for the €49 incl. VAT full PDF report.Have a code? Enter it at checkout.
€49 incl. VAT once-off PDF, no account required
Refund requests are reviewed under the published refund policy
Derived from public planning records and linked source documents
PlanIntelPlanning precedent preview

Planning precedent report

Virginia College , Lake Road Virginia , Co. Cavan

One-off house / within 5 km where a location match is available

Preview

Local planning pattern

7% of nearby decided applications were refused. The preview found 302 nearby planning records within 5 km where a location match is available.

Matched source
2360085
Project type
One-off house
Coverage
5 km radius
302Nearby applications
7%Refused
280Conditional grants
0Refusal reasons

Top refusal reasons nearby

No reasons on record yet

More refusal reasons are being processed from public planning records.

Nearest similar decisions

2360085

For (i) The construction of a new three-storey extension consisting of a new 4 no. Classbase Special Educational Needs facility and ancillary accommodation, 11 no. general classrooms, specialty classrooms and general offices. Building to be linked to the existing post primary school. (Total Area = 4538 sq.m), (ii) Refurbishment and extension of existing GP Hall (82 sq.m - extension), (iii) The demolition of existing 1960 school building (1793sq.m) to accommodate 2 No. Ball-courts, 24 No. Bicycle stands and other associated site works, (iv) 27 no. relocated and 9 no. proposed car parking spaces with associated bus set down areas, (v) The installation of 46 No. of south facing photo-voltaic panels to the extension roof, (vi) The construction of a 26 sq.m ESB Substation, (vii) a Natura Impact Statement has been completed as part of this application

Granted0.0 km06 March 2024
2560166

For demolition and replacement of existing sunroom to side of dwelling,- Construction of new single storey extension to side of dwelling,- Construction of new dormer extension to rear of first floor,- Alterations to front façade to include new windows, - Associated site services & landscaping

Granted0.1 km04 June 2025
22489

For works to upgrade the Virginia Wastewater Treatment Plant off the N3 in the townland of Rathardum and Terminal Pumping Station off New Street, in the townland of Virginia, Virginia, Co. Cavan. The proposed development comprises upgrade works to the existing terminal pumping station (TPS) site and waste water treatment plant (WWTP) site. The development at the WWTP site will consist of 1) provision of inlet works; 2) provision of a control storm water overflow chamber; 3) provision of stormwater storage tank; 4) provision of Dual function Overflow outfall to Lough Ramor to replace existing (to be decommissioned) SWO outfall at the TPS; 5) provision of tertiary treatment system (tanks and filter) with all associated ancillary works; 6) provision of 4 no. buildings for operating equipment; 7) provision of wash water recycle system to clean equipment; 8) provision of outfall pump station; 9) demolition of existing sludge tank and replacement with sludge thickening unit and sludge holding tank; 10) provision of biological treatment tank; 11) provision of below ground pump chambers and process drainage sumps; 12) provision of odour control unit and above ground duct work; 13) provision of back-up generator with bunded diesel tank; 14) provision of an ESB substation; 15) provision for internal hardstanding accessways; and 16) ancillary and associated development including removal of existing trees and vegetation on the site, and replacement tree planting, minor structural alterations to existing tanks, and mechanical and electrical service connections. The development at the TPS site will consist of 1) demolition and replacement of existing foul pump sump; 2) provision of additional rising main across the River Blackwater to the WWTP; 3) decommissioning of the existing stormwater overflow; 3) repurposing the existing stormwater settlement tank as emergency storage tank, with minor demolition works and increased height of tank; 4) mass fill to raise floor levels of inlet chambers; 5) provision of high level emergency overflow to River Blackwater; 6) replacement of existing boundary palisade fence with new boundary wall along the north, west and south boundary of the TPS, and a fence along the river edge on the eastern boundary. The site will be extended to the north-west; 7) upgrade to existing site entrances; 8) provision of 3 no. kiosks for operating equipment and welfare facilities; 9) provision of odour control unit and above ground duct work; and 10)

Granted0.2 km16 October 2023
2560509

For an extension to the rear of an existing dwelling, two storey extension with toilet on ground floor, bedroom and toilet on first floor, create opening in existing stone wall to provide for 2 no. car parking spaces to the rear and connection to existing public services. Existing dwelling is a Protected Structure as listed under the Record of Protected Structures in the Cavan County Development Plan 2022-2028, Reference Number CV0889

Refused0.2 km20 October 2025
2053

To carry out works to existing protected structure (CV39035) comprising of the following; (A) subdivide the building into 2 No. commercial units (Change of Use was previously approved under Planning Application Ref. No. 08/1082), (B) demolish single storey extension to the rear, (C) construct extended single storey extension to the rear, (D) provide car parking in rear yard, (E) carry out alterations and upgrades to the existing building, (F) erect signage, (G) along with all associated site works

Granted0.3 km14 April 2020
2460382

For change of use of existing public house known as ‘The Coachman Inn’ Main Street, Virginia to 2 no. Retail / Commercial units (referenced as units 3 and 4 on submitted application) including signage, alterations to elevations & internal alterations. Planning Permission is also sought to alter shop front and entrances to existing units (referenced as units 1 and 2 on submitted application) & all associated works

Granted0.3 km09 October 2024

The full report adds the full list of similar grants and refusals, source quotes, document links, and a shareable PDF summary.

Policy and design risk

Full PDF

Source document extracts

Full PDF

Comparable decision table

Full PDF

Submission strategy

Full PDF
Ready to generate the full report?€49 incl. VAT once-off PDF, no account required