Applications tied to the site
Partial coverage6 register records are within the point-match tolerance; a parcel boundary is needed to treat this as exact.
6 matchedSite planning risk brief
One-off house / within 5 km where a location match is available
Executive snapshot
10% of nearby decided applications were refused. The site check found 820 decisions within 5 km, 6 exact-site or onsite candidate records, and 26 structured appeals.
Evidence maturity
Each section reports its own coverage. “Not yet covered” means no conclusion is drawn while source datasets or policy extraction are still being loaded.
6 register records are within the point-match tolerance; a parcel boundary is needed to treat this as exact.
6 matchedCurrent indexed zoning and settlement layers are intersected with the selected site where coverage exists.
Current section-and-page citations have not yet been loaded for this authority.
Each layer reports its own coverage; missing coverage never appears as a clean result.
0 prompts are backed by extracted nearby decision evidence; all prompts remain checks, not predictions.
26 structured nearby appeal records.
26 matchedHistoric extracted references are not presented as current policy; verified citations are still being loaded.
Open preview
Open preview
RETENTION AND COMPLETION OF ATTIC CONVERSION TO HABITABLE ROOMS AND RETENTION OF ALTERATIONS MADE TO ELEVATIONS
(1) RETENTION OF SINGLE STOREY DOMESTIC GARAGE AND (2) RETENTION AND COMPLETION OF SINGLE STOREY EXTENSION, UNDER CONSTRUCTION, TO THE REAR OF EXISTING DWELLING, CONSISTING OF ENSUITE BEDROOM INCLUDING MINOR ELEVATIONAL REVISIONS AND (3) ALL ASSOCIATED DEVELOPMENT WORKS
STEEL FRAMED COMMERCIAL STORAGE SHED FOR PLUMBING SUPPLIES AND PERMISSION FOR CONSTRUCTION OF A TARMACADAM HARDSTAND AREA FOR STAFF CARPARKING AND ALL ASSOCIATED SITE DEVELOPMENT WORKS
(1) CONSTRUCTION OF APPROXIMATELY 1,150M OF 375MM DIAMETER BELOW GROUND GRAVITY SEWER UPGRADES ON COCKHILL ROAD FROM THE EXISTING WESTBROOK PUMPING STATION ON WESTBROOK ROAD TO A POINT APPROXIMATELY 140M NORTHEAST OF THE OLD COCKHILL BRIDGE ON THE COCKHILL ROAD, (2) UPGRADES TO THE EXISTING WESTBROOK PUMPING STATION TO INCLUDE THE CONSTRUCTION OF A NEW SUBTERRANEAN STORM STORAGE TANK; SUBTERRANEAN STORM OVERFLOW CHAMBER AND SCREEN; STORM RETURN PUMPS; 5.0M HIGH ORNATE VENTILATION STACK; IMPROVEMENTS TO THE EXISTING SITE ENTRANCE; A TEMPORARY CONSTRUCTION ACCESS FROM THE COCKHILL ROAD (R-238); LANDSCAPING OF THE SITE; NEW BOUNDARY WALL/FENCE AND ALL ASSOCIATED SITE WORKS. A NATURA IMPACT STATEMENT (NIS) ACCOMPANIES THE APPLICATION
CONSTRUCTION OF A NEW TWO-STOREY 21 BEDROOM RESIDENTIAL HOSTEL WITH A MIXTURE OF 9 SINGLE ROOMS, 6 DOUBLE ROOMS AND 2 NO. FAMILY SUITES (EACH CONTAINING 1 NO. DOUBLE ROOM AND 2 NO. SINGLE ROOMS) WITH RECEPTION AREA, DINING AREA, 2 NO. KITCHENETTE AND LOUNGE, LAUNDRY ROOM; TOGETHER WITH ASSOCIATED SITE WORKS AND CONNECTION TO EXISTING SERVICES
CONSTRUCTION OF A GRANNY FLAT WITH CONNECTION TO MAIN SEWER AND ALL ASSOCIATED SITE WORKS
The brief summarizes the pattern across all 820 matched decisions within 5 km and includes up to 80 detailed comparables (40 nearest refusals and 40 nearest grants), with extracted reasons, quotes, and available source links. €29 incl. VAT.
Source match
Matched from public planning record 1851479The site brief adds up to 80 nearest detailed grants and refusals, extracted source evidence, document links, and a shareable risk summary.
Included in site brief
Included in site brief
Included in site brief
Included in site brief