Free preview / €29 incl. VAT site brief

Site planning risk brief

Fix the brief to an Eircode, a dropped pin or a drawn site boundary. PlanIntel then checks the planning register, available spatial layers, appeals and current indexed policy evidence.
See sample PDF

Define the land to check

Porterstown , Kill , Co. Kildare Y2D 9W91.Opens secure checkout for the €29 incl. VAT site risk brief. Promotion codes can be entered at checkout.
€29 incl. VAT once-off PDF, no account required
Refund requests are reviewed under the published refund policy
Derived from public planning records and linked source documents
PlanIntelSite risk brief preview

Site planning risk brief

Porterstown , Kill , Co. Kildare Y2D 9W91.

One-off house / within 5 km where a location match is available

Preview

Local planning pattern

27% of nearby decided applications were refused. The site check found 461 decisions within 5 km, 1 exact-site or onsite candidate record, and 101 structured appeals.

Matched source
171376
Project type
One-off house
Coverage
5 km radius

What this site brief can substantiate today

Each section reports its own coverage. “Not yet covered” means no conclusion is drawn while source datasets or policy extraction are still being loaded.

Applications tied to the site

Partial coverage

1 register record is within the point-match tolerance; a parcel boundary is needed to treat this as exact.

1 matched

Zoning and settlement

Not yet covered

Current indexed zoning and settlement layers are intersected with the selected site where coverage exists.

Rural-housing policy

Not yet covered

Current section-and-page citations have not yet been loaded for this authority.

Flood, heritage, ecology and archaeology

Not yet covered

Each layer reports its own coverage; missing coverage never appears as a clean result.

Access, road and wastewater prompts

Partial coverage

0 prompts are backed by extracted nearby decision evidence; all prompts remain checks, not predictions.

Structured appeal history

Confirmed coverage

101 structured nearby appeal records.

101 matched

Current policy citations

Not yet covered

Historic extracted references are not presented as current policy; verified citations are still being loaded.

461Nearby applications
1Site-linked candidates
27%Nearby refused
101Structured appeals

Top refusal reasons nearby

No reasons on record yet

More refusal reasons are being processed from public planning records.

Nearest planning decisions

171376

Construction of a detached dwelling (part single/part two-storey) with waste water treatment plant and percolation area, associated landscaping and boundary treatment works, a new single storey garage and alterations to an existing vehicular entrance off of the road at Willow Lodge

Granted0.0 km18 April 2018
23276

For a second phase of the existing grid system services facility within the existing grid system services facility within the existing site area of c1.95 hectares, which was granted via reference number 18/247. The second phase will utilise all existing infrastructure, including the EirGrid gird connection infrastructure, site roads, 110kV substation, compounds, and all ancillary services. The proposed new works will consist of the installation and operation of battery energy units, including 1 no. customer switchgear container which will be connected to the national grid, via the existing infrastructure,electrical transformers and inverter units, underground cabling and ducting, boundary fencing, security entrance gates, CCTV, internal access road and all associated ancillary infrastructure on land at

Granted0.5 km11 May 2023
18247

Development of a grid system services facility within a total site area of up to 1.95 hectares, to include 1no. TSO compound including 1no. single storey TSO electrical substation building and 1no. single storey customer substation, 1no. customer switchgear, electrical inverter /transformer station modules, containerised battery storage modules on concrete support structures, heating, ventilation and air conditioning units (HVAC units), access tracks and upgraded site entrance, associated electrical cabling and ducting, security gates, perimeter security fencing, CCTV security monitoring system, culverts and landscaping works and all associated ancillary infrastructure

Granted0.5 km03 May 2018
20745

The development of a new electrical substation and additional equipment in the existing ESB Kilteel 110kV Substation to facilitate the connection of the Porterstown Battery Storage Facility (Planning Ref 18/247) The total site area is 1.2 hectares. The new electrical substation will include 1 control building (GRP Containerised Substation), a 110kV transformer, surge arresters, instrument transformers, a 110kV busbar connecting to the ESB substation, a lightning mast and other electrical equipment to be installed on concrete support structures. Additional features will include palisade fencing, security gates, access tracks, external lighting, drainage, associated electrical cabling and ducting, CCTV security monitoring system, landscaping and all associated ancillary infrastructure. The additional equipment to be installed in the ESB substation to facilitate the connection of the new substation will include a 110kV busbar extension, a 110kV transformer bay, a 110kV coupler bay, a 110kV busbar connecting to the new substation, an interface kiosk, palisade fencing, a lightning mast and all associated ancillary infrastructure required for the connection

Granted0.5 km01 September 2020
25131

For (A) Retention of existing 3754 square meters of the hard standing area consisting of a mix of concrete, blacktop and gravel and permission for upgrading of the same hard standing area for the parking of up to twenty trucks and trailers as per this application, (B) Retention of use of same hard standing area for use of parking of up to twenty trucks and trailers, (C) The retention of 898 square meters of existing buildings, (D) The retention of use for these same buildings at C above for use for overnight parking of trucks and trailers and the storage of dry spare parts, components and towing equipment necessary for the trucks and trailers, (E) Retention of the use of a drive which serves the home of the directors of Kill Haulage as a means of access to the public road from the hard standing areas and buildings, the subject of this application, (F) All ancillary works

Refused0.5 km24 September 2025
25120

To install a standby industrial diesel generator under proposed solar panels. The generator, to provide standby power generation, will incorporate a bunded fuel tank and be located within a mesh fence. The proposed solar panels will be attached to a steel frame to be erected over the generator (covering an area of approximately 22 sq.m., to a maximum height of 4.7 metres above ground level). Works to include all ancillary development works, all located within an existing fenced compound

Granted0.6 km25 August 2025

The brief summarizes the pattern across all 461 matched decisions within 5 km and includes up to 80 detailed comparables (40 nearest refusals and 40 nearest grants), with extracted reasons, quotes, and available source links. €29 incl. VAT.

The site brief adds up to 80 nearest detailed grants and refusals, extracted source evidence, document links, and a shareable risk summary.

Exact site history and boundary checks

Site brief

Policy and mapped constraints

Site brief

Appeals and comparable decisions

Site brief

Deterministic risk prompts

Site brief
Ready to get the site risk brief?€29 incl. VAT once-off PDF, no account required