Applications tied to the site
Partial coverage2 register records are within the point-match tolerance; a parcel boundary is needed to treat this as exact.
2 matchedSite planning risk brief
One-off house / within 5 km where a location match is available
Executive snapshot
9% of nearby decided applications were refused. The site check found 686 decisions within 5 km, 2 exact-site or onsite candidate records, and 46 structured appeals.
Evidence maturity
Each section reports its own coverage. “Not yet covered” means no conclusion is drawn while source datasets or policy extraction are still being loaded.
2 register records are within the point-match tolerance; a parcel boundary is needed to treat this as exact.
2 matchedCurrent indexed zoning and settlement layers are intersected with the selected site where coverage exists.
Current section-and-page citations have not yet been loaded for this authority.
Each layer reports its own coverage; missing coverage never appears as a clean result.
0 prompts are backed by extracted nearby decision evidence; all prompts remain checks, not predictions.
46 structured nearby appeal records.
46 matchedHistoric extracted references are not presented as current policy; verified citations are still being loaded.
Open preview
Open preview
EXTENSIONS AND MODIFICATIONS TO THE PERMITTED BIOPHARMACEUTICAL MANUFACTURING FACILITY [PLANNING APPLICATION REFERENCE NUMBER 21/701], CURRENTLY UNDER CONSTRUCTION. A 10 YEAR PERMISSION IS BEING SOUGHT FOR THIS PROPOSED DEVELOPMENT. THE PROPOSED DEVELOPMENT SITE MEASURES APPROXIMATELY 8.1 HECTARES, LOCATED TO THE WEST OF THE EXISTING OPERATIONAL ZOETIS FACILITY WITHIN THE IDA SRAGH TECHNOLOGY PARK, RAHAN ROAD, TULLAMORE, COUNTY OFFALY. THE PROPOSED DEVELOPMENT CONSISTS OF THE FOLLOWING: (1) A SINGLE STORY BIOPHARMACEUTICAL MANUFACTURING BUILDING EXTENSION SIZED APPROXIMATELY 8,090 SQUARE METRES INCLUDING A PLANT ROOM MEZZANINE LOCATED TO THE EAST OF THE EXISTING BUILDING AND A SINGLE STOREY WAREHOUSE BUILDING EXTENSION WITH MEZZANINE PLANTROOM SIZED APPROXIMATELY 754 SQUARE METRES LOCATED TO THE WEST OF THE EXISTING FACILITY (ALL UNDER CONSTRUCTION). THE BUILDING IS APPROXIMATELY 14.5 METRES HIGH TO MATCH THE EXISTING BUILDING HEIGHT, WITH ROOF MOUNTED EQUIPMENT AND STACKS INCLUDING 3 ADDITIONAL BOILER STACKS 18 METRES HIGH. (2) SITE WORKS CONSIST OF CAR PARKING FOR APPROXIMATELY 65 ADDITIONAL CAR SPACES, INCLUDING ACCESSIBLE SPACES AND ELECTRICAL CHARGING, A SINGLE STOREY PUMP HOUSE SIZED 53 SQUARE METRES APPROXIMATELY AND 6 METRES HIGH, EXTERNAL YARD MOUNTED PLANT AND EQUIPMENT, EXTERNAL TANKS, AND SITE LIGHTING. (3) ANCILLARY SITE WORKS INCLUDING A RECYCLING COMPOUND, THE DIVERSION OF EXISTING POWER LINES, TEMPORARY CONTRACTOR’S COMPOUND AND LOCAL TEMPORARY CONTRACTOR PARKING, THE USE OF EXISTING SITE ENTRANCES, INTERNAL ROADWORKS, UNDERGROUND SERVICES, BICYCLE SHELTER EXTENSION, LANDSCAPED BERMS AND LANDSCAPING, ADDITIONAL BUILDING MOUNTED AND GROUND SIGNAGE, SECURITY FENCING AND GAS STORAGE. THIS APPLICATION CONSISTS OF A DEVELOPMENT FOR AN ACTIVITY FOR WHICH A LICENCE UNDER PART IV OF THE ENVIRONMENTAL PROTECTION AGENCY ACT 1992 (AS AMENDED BY THE PROTECTION OF THE ENVIRONMENT ACT, 2003) IS REQUIRED. AN ENVIRONMENTAL IMPACT ASSESSMENT REPORT (EIAR) ACCOMPANIES THIS PLANNING APPLICATION
(1) A SINGLE STOREY BIOPHARMACEUTICAL MANUFACTURING BUILDING SIZED APPROXIMATELY 8,510 SQUARE METRES INCLUDING A PLANT ROOM MEZZANINE. THE BUILDING IS APPROXIMATELY 14.5 METRES HIGH WITH ROOF MOUNTED EQUIPMENT AND STACKS INCLUDING 3 BOILER STACKS 18 METRES HIGH. (2) SITE WORKS CONSIST OF CAR PARKING FOR APPROXIMATELY 152 ADDITIONAL CAR SPACES, INCLUDING ACCESSIBLE SPACES AND ELECTRICAL CHARGING, A SINGLE STOREY SPRINKLER PUMP HOUSE SIZED 110 SQUARE METRES APPROXIMATELY AND 6 METRES HIGH, EXTERNAL YARD MOUNTED PLANT AND EQUIPMENT, EXTERNAL TANKS, AND SITE LIGHTING AND A SINGLE STOREY ELECTRICAL BUILDING SIZED 60 SQUARE METRES APPROXIMATELY AND 6 METRES HIGH. (3) ANCILLARY SITE WORKS INCLUDING TEMPORARY CONTRACTORS' COMPOUND AND LOCAL TEMPORARY CONTRACTOR PARKING, THE USE OF EXISTING SITE ENTRANCES, INTERNAL ROADWORKS, UNDERGROUND SERVICES, LOADING DOCKS, BICYCLE SHELTER, LANDSCAPED BERMS AND LANDSCAPING, BUILDING MOUNTED AND GROUND SIGNAGE, A SURFACE WATER ATTENUATION POND, SECURITY FENCING AND GAS STORAGE. THIS APPLICATION CONSISTS OF A DEVELOPMENT FOR AN ACTIVITY FOR WHICH A LICENCE UNDER PART IV OF THE ENVIRONMENTAL PROTECTION AGENCY ACT 1992 (AS AMENDED BY THE PROTECTION OF THE ENVIRONMENT ACT, 2003) IS REQUIRED. AN ENVIRONMENTAL IMPACT ASSESSMENT REPORT (EIAR) ACCOMPANIES THIS PLANNING APPLICATION
THE CONSTRUCTION OF A NEW SINGLE STOREY INDUSTRIAL EXTENSION TO THE REAR (NORTH SIDE) OF THE EXISTING INDUSTRIAL BUILDING AND ALL ASSOCIATED SITE DEVELOPMENT WORKS. THE WORKS ARE PROPOSED ON A SITE WHICH IS A SEVESO III, LOWER TIER SITE AND AN EPA LICENCED FACILITY UNDER THE RADIOLOGICAL ACT, 1991 (IONISING RADIATION) ORDER S.I. NO 125 OF 2000, LICENCE NO L2706-02
The construction of a new single-storey extension to the Goods-In Warehouse to the front (southern) elevation of the existing building, the demolition of existing office accommodation and construction of replacement offices along the new front elevation, the extension of the existing car park to provide 34 additional parking spaces, and the incorporation and reconfiguration of an area of existing public amenity land to the south-west, including the relocation of the footpath, seating, and trees, together with landscaping and all associated site development works. The works are proposed on a site designated as a Seveso III Lower Tier establishment and licensed by the EPA (Licence No. L2706-02)
(IV.) LINK CORRIDOR AND SPRINKLER PUMPHOUSE AS CONSTRUCTED. (I.) PERMISSION FOR THE CONSTRUCTION OF A NEW EXTENSION (6418M2) TO THE EXISTING FACILITY TO INCLUDE ETHYLENE OXIDE MEDICAL STERILISATION CHAMBERS, WAREHOUSING, LABORATORY AND ANCILLARY ACCOMMODATION AND ALL ANCILLARY WORKS. (II.) PERMISSION FOR A NEW VEHICULAR ENTRANCE, CAR PARK, DEPRESSED LOADING DOCKS AND CANOPY, SERVICE YARD AND GAS STORAGE AREA AND ASSOCIATED PLANT AND EQUIPMENT, SEPARATE STAND-ALONE BOILER ROOM, COVERED WALKWAY LINK, PROVISION, A CANOPY TO EXISTING E-BEAM FACILITY AND ALL ASSOCIATED SITE WORKS. (III.) AMENDMENT TO PLANNING REFERENCE PL2/16/358 IN TERMS OF OMITTING THE PERMITTED TWO STOREY LABORATORY BUILDING AND ANCILLARY ACCOMMODATION AND RELOCATING AND AMENDING IT UNDER (I) ABOVE. THE WORKS ARE PROPOSED ON A SITE WHICH IS A SEVESO III, LOWER TIER SITE AND AND AN EPA LICENCED FACILITY UNDER THE RADIOLOGICAL PROTECTION ACT, 1991 (IONISING RADIATION) ORDER, S.I. NO. 125 OF 2000, LICENCE NO L2706-02
RECONFIGURATION OF EXISTING BUNGALOW TYPE DWELLING TO A NEW STOREY AND HALF TYPE DWELLING INCORPORATING ELEVATIONAL CHANGES AND ALL ANCILLARY SITE WORKS
The brief summarizes the pattern across all 686 matched decisions within 5 km and includes up to 80 detailed comparables (40 nearest refusals and 40 nearest grants), with extracted reasons, quotes, and available source links. €29 incl. VAT.
Source match
Matched from public planning record 22676The site brief adds up to 80 nearest detailed grants and refusals, extracted source evidence, document links, and a shareable risk summary.
Included in site brief
Included in site brief
Included in site brief
Included in site brief