Applications tied to the site
Partial coverage9 register records are within the point-match tolerance; a parcel boundary is needed to treat this as exact.
9 matched| PlanIntel brief | PlanningCheck | |
|---|---|---|
| Price | €39 incl. VAT | €49 |
| Nearby decisions | Up to 80 detailed (40 refusals + 40 grants) | Not stated |
| AI planning chat | 5 messages/day free | None |
| Saved-site alerts | Free | None |
Site planning risk brief
One-off house / within 5 km where a location match is available
Executive snapshot
19% of nearby decided applications were refused. The site check found 1,208 decisions within 5 km, 9 exact-site or onsite candidate records, and 517 structured appeals.
Evidence maturity
Each section reports its own coverage, per county. “Not yet covered” means the source dataset is not loaded for this local authority, so the brief draws no conclusion there and says where to check — it never reads as “no constraint found”.
9 register records are within the point-match tolerance; a parcel boundary is needed to treat this as exact.
9 matched1 of 2 layers are loaded for South Dublin County Council and were intersected with the site; settlement boundary is not loaded and no conclusion is drawn for it.
1 matchedNo verified rural-housing citation is loaded for South Dublin County Council, so this brief makes no current policy claim and relies on decision history.
3 of 4 layers are loaded for South Dublin County Council and were intersected with the site; flood is not loaded and no conclusion is drawn for it.
3 matched0 prompts are backed by extracted nearby decision evidence; all prompts remain checks, not predictions.
517 structured nearby appeal records.
517 matchedCitations are current-dated and carry policy name, section, page and source URL from the South Dublin County Council development plan.
1 matchedOpen preview
Open preview
Extend the integrated ancillary offices on 2 floors within the existing warehousing Unit B1 (original Reg. Ref: SD07A/0223). The office extension comprises 48sq.m additional ancillary office on ground floor (provided from a change of use of existing warehouse area) and 48sq.m additional ancillary office area at first floor. There are no external alterations to the building as a result of the provision of this additional internal office accommodation and existing car parking provided on site remains sufficient in facilitating the extended building.
Alterations to existing granted Planning Permissions (Reg. Ref. SD23A/0317 & SD24A/0140) for development at Site N, Jordanstown Road, Aerodrome Business Park, Rathcoole, Co. Dublin. The subject alteration proposal incorporates the following: Alteration at Ground Floor Plan as follows: Change of Use of 12m2 of Ancillary Office area to Staff Facilities area. Alterations at First Floor Plan as follows: Change of use of 34m2 of Ancillary Office area to Staff Facilities area. Mezzanine Plant Area increased by 252m2. Addition of 62m2 of External Plant Area. Overall building height reduced from 13m to 9.8m due to clear internal headroom reducing from 10m to 6.8m plus roof lights now omitted from Roof Plan. Building elevation revisions due to the related layout changes. Relocation of ESB Substation (total area of 32.95m2) on the site. Site Plan and associated drainage updates based on all the above adjustments. NOTE: All other previously granted elements remain as per existing granted Planning Permissions described above.
Alterations to an existing granted Planning Permission (Reg. Ret SD23A10317) for development at Site N, Jordanstown Road, Aerodrome Business Park, Rathcoole, Co. Dublin. The subject alteration proposal incorporates the following: 1. Change of Use of Warehousing use to Light Industrial use. 2. While the building footprint will remain as per the above referenced granted planning application (with minor position relocation on site), the overall building area changes from 89lsqm to 1,24Osqm following the proposed floor areas breakdown: A. Ground Floor Light Industrial Area: 557m2 B. Ground Floor Ancillary Office and Staff Facilities: 283m2 C. First Floor Ancillary Offices and Staff Facilities: 283m2 D. Mezzanine Level Plant Area: I I7m2 E. Overall building height reduced from 15m to 13m due to clear internal headroom reducing from 12m to 10m. F. Building elevation revisions due to internal layout changes. 3. Site plan revisions to facilitate the specific Light Industrial use as follows: A. Carparking layout revisions, previously 3, now 10 spaces. B. Site access and egress location will remain as per the granted planning application with the access gate now reduced from 9m to 7.5m. C. The facility will no longer require HGV goods doors, so van access and an associated goods door are now included in this revision to suit this new specific use with the previously granted HGV goods door being removed. D. Site landscaping adjustments to reflect the related adjustments. E. Site drainage adjustments to reflect the related adjustments.
The land is bounded to the North by undeveloped land, to the South by warehousing development, to the East by Jordanstown Road and to the West by warehousing development. The development will comprise the provision of a Warehouse with Ancillary Office and Staff Facilities and associated site development. The building will have a maximum external height of 15m with a gross floor area of 891 sqm including warehouse area (789 sqm), ancillary staff facilities (51 sqm) and ancillary office area (51 sqm). The development will also include: vehicular access/egress via Jordanstown Road; a pedestrian access via Jordanstown Road; 3 no. ancillary car parking spaces including EV and accessible parking spaces; level access good doors; external canopies; hard and soft landscaping; external lighting; boundary treatments; and all associated site development works above and below ground.
The installation of Photovoltaic Panels (PV) to be mounted on the rooftop of an existing warehouse building. the proposed development includes the provision of 630 kWp of photovotaic solar panels, fixing & mounting systems, inverters, underground cabling and ducting and all associated ancillary infrastructure. PV panels will not extend above parapet line. The installation and operation of the proposed development will facilitate the generation of renewable electricity which will be utilised on - site
Change of use of 4sq.m of warehouse floor area to Staff Facilities floor area at the ground floor plan and minor adjustments to the internal Staff Facilities layout to accommodate Part M requirements (no associated area alterations); elevational changes, addition of 2 level access doors to the building's northern elevation and 2 level access doors to the building's eastern elevation; addition of 1 fire escape door from the ancillary office block to the building's eastern elevation; associated site plan & drainage adjustments.
The brief summarizes the pattern across all 1,208 matched decisions within 5 km and includes up to 80 detailed comparables (40 nearest refusals and 40 nearest grants), with extracted reasons, quotes, and available source links. €39 incl. VAT.
Source match
Matched from public planning record SD18A/0214The site brief adds up to 80 nearest detailed grants and refusals, extracted source evidence, document links, and a shareable risk summary.
Included in site brief
Included in site brief
Included in site brief
Included in site brief