Loughtee House, Golf Links Road Drumelis, Co. Cavan H12 YX56
For an extension (25.45 sq. m) to the single storey kitchen and living area to the side including minor amendments to the front and rear elevationsDecision record indexed
Lands at Billis and Drumalee Townlands, Cootehill Road, Cavan Town
The development will consist of the provision of a total of 134no. residential units along with provision of a crèche. Particulars of the development comprise as follows: (a) Site excavation works to facilitate the proposed development to include excavation and general site preparation works. (b) The provision of a total of 109no. residential dwellings which will consist of 6no. 1bed units, 39no. 2 bed units, 59no. 3 bed units and 5no. 4 bed units. The residential dwellings range in height from one to two storeys. (c) The provision of a total of 25no. duplex apartment units consisting of 15no.1 bed units and 10no. 2bed units. The duplex apartment units range in height from two to three storeys. (d) Provision of a single storey creche with associated parking, bicycle and bin storage. (e) Provision of associated car parking at surface level via a combination of in-curtilage parking for dwellings and via on-street parking for the creche and duplex apartment units. (f) Provision of electric vehicle charge points with associated site infrastructure ducting to provide charge points for residents throughout the site. (g) Provision of associated bicycle storage facilities at surface level throughout the site and bin storage facilities. (h)The provision of an internal culvert along with decommissioning of existing drainage channel within the site. Culvert works to include for provision of a headwall at the outfall to the watercourse. (i) Creation of a new access point from the public road with associated works to include for a connections to the existing public footpath along with a pedestrian crossing point. (j) Provision of internal access roads and footpaths and associated works to include for regrading of site levels as required. (k) Provision of residential communal open space and public open space areas to include formal play areas along with all hard and soft landscape works with public lighting, planting and boundary treatments to include boundary walls, railings & fencing. (l) Internal site works and attenuation systems which will include for provision of a hydrocarbon and silt interceptor prior to discharge. (m) All ancillary site development/construction works to facilitate foul, water and service networks for connection to the existing foul via a rising main and provision of a foul pumping station, water connections and ESB network connection to include for provision of a substation. A Natura Impact Statement (NIS) has been preparedDecision record indexed
No. 4 The Beeches, Ture Td Ballyconnell, Co. Cavan H14 KV99
To retain dwelling as constructed with changes to floor plans, elevations, distances to site boundaries to the dwelling previously granted 00/499 (site No. 4 of 4 No. houses)Decision record indexed
For a detached 2 storey arts and craft library and home office/studio located in garden to rear of existing cottage, clad in fibre cement agricultural cladding with aluclad doors and windows Significant further information and revised plans have been submitted.Decision record indexed
Variation to previously approved plans ref: 22/120 for a detached 1 storey arts & craft library and home office/studio located in garden to rear of existing cottage, clad in fibre cement agricultural cladding with aluclad doors and windows this will involve the relocation, reduction in the area and height of the approved plansDecision record indexed
Farnham Estate Spa & Golf Resort, Farnham, Co. Cavan
For Modifications to the spa upgrade previously approved under planning permission register no. 19/522. The modifications include the following: • An increase in the number of pod cabins from 6 to 9 • Modifications to the pod cabin sizes, layouts and materials. • The addition of a covered outdoor relaxation area • The addition of a relaxation barn • Modifications to site, thermal village layout, site works, services and landscaping throughout The proposed modifications result in a total uplift of 332sqm in area to the previously approved scheme. Significant further information and revised plans have been submitted.Decision record indexed
For the following: (1) A single storey 75sqm extension at ground level to the existing health spa to accommodate additional changing facilities along with renovations to existing changing rooms, toilets and accessible toilet facilities; (2) A single storey 177sqm extension at lower ground level to provide additional relaxation areas near the main pool area; (3) Extended outdoor pool terrace and new hydrotherapy pool along with a new single storey plant room of 61.5sqm to be constructed into the hillside adjacent to terrace; (4) Outdoor 'Thermal Village' comprising of a single storey pod cabin structure of 19sqm containing a sauna, a single storey pod cabin structure of 19sqm containing a steam room, a single storey pod cabin structure of 19sqm containing accessible toilet, store room, and plant, repairs to existing stone ruin & external deck area with new hydrotherapy pool; (5) Outdoor 'Relaxation Zone' comprising of 3no. single storey pod cabin structures of 19sqm each containing an indoor relaxation area along with an outdoor private deck area; (6) Outdoor 'Wet Zone' comprising of 2no. external deck relaxation areas & 2no. external jacuzzies; (7) Associated landscaping works including excavation and enhancement of existing man-made lake, provision of walking trails, deck areas and soft landscaping throughout, along with all associated site works, plant and services throughout. All at Farnham Estate Spa and Golf Resort, Farnham, Co. Cavan (Protected Structure)Decision record indexed
Retention permission is sought for a single-storey domestic extension comprising of a kitchen / dining area, living room, utility and bathroom along with all ancillary works. Retention permission is also sought for elevational changes to an existing garage on the siteDecision record indexed
Farnham Estate Spa & Golf Resort, Farnham, Co Cavan
For the construction of a new single storey biomass boiler facility located in the vicinity of the existing staff car park, comprising a boiler house (38sqm) and associated fuel store (27sqm) on a hardstanding area and surrounded by a steel railing, along with associated site works, services and landscaping. These works take place within the curtilage the protected structureDecision record indexed
Is sought for the following (1) Permission to alter floor plans and elevation to house No's. 22, 23 and 24 on all associated works, (2) Permission to RETAIN alterations to floor plans and elevation to house No. 25 to include front porch, rear extension and rear attic window (previous approved planning reg 19/158 & 17/103 relates)Decision record indexed
For the development of construction of fully serviced bungalow type dwelling on existing foundations of previously approved Planning. Ref. 04/1850 and 06/665 with connection to existing services and all ancillary worksDecision record indexed
For single storey dwelling, detached domestic garage, new entrance, effluent treatment system, percolation area and associated site worksDecision record indexed
For the erection of a single storey dwelling with rear attached carport, new site entrance, wastewater treatment system, percolation area and all ancillary site works. SIGNIFICANT FURTHER INFORMATION HAS BEEN RECEIVED.Decision record indexed
Retain changes to elevations and sections on Planning Ref. 18/305 as granted (changes include part of shed has roof omitted - Animal holding area now open, pitch and ridge heights reduced- No change in floor area)Decision record indexed
To retain and complete alterations to floor plans & elevations to house no. 22 (previous approved planning reg: 19/158 & 17/103)Decision record indexed
Construct new part two-storey and part single storey dwelling house, form new vehicular site entrance onto public roadway, installation of approved proprietary wastewater treatment system and percolation area, together with all associated site development worksDecision record indexed
Carry out alterations to previously approved planning reg no 19/228 as follows: change house types to plots 13a and 13b (2 no. three bed single store semi-detached dwellings) to 2 no. three bed detached bungalows with optional habitable attic accommodation, connect to existing mains services, associated siteworks and all ancillary worksDecision record indexed
For conversion of existing attached domestic garage to habitable accommodation, modification of existing garage door opening to form new window on front elevation and all ancillary worksDecision record indexed
To retain the following, (A) Single storey lean to conservatory to front of existing dwelling and (B), Detached domestic storage shed & all ancillary worksDecision record indexed
To carry out renovations and extensions to existing two storey dwelling. Works to include erection of extensions to front and side of the existing dwelling, raising of roof level, associated alterations to elevations and all ancillary site worksDecision record indexed
For (a) a single storey modular structure at first-floor level containing a laboratory (b) PERMISSION for the construction of an extension to this modular building comprising a further single storey modular structure at first floor level containing a new laboratory; connection to existing services, and all associated site development worksDecision record indexed
To refurbish existing derelict cottage, demolish existing rear extension and erect single storey side attached extension & front Porch, alterations to building elevations and internal layout, install wastewater treatment system & Ecoflo Coco Filter and all ancillary site worksDecision record indexed
For Electrical Infrastructure Upgrade Works on the hospital campus which includes: 2no. new Substations. Substation Building 1 is located to the south west of the site and includes an associated compound and a containerised generator. Substation Building 2 is located to the north of the site and includes an associated compound and a containerised generator. In the location of Substation Building 2 works also include a new water tank, pumphouse, a new oil tank with associated fencing, and a gas compound containing 4no. gas tanksDecision record indexed
For a 5,236 sq. m. three storey extension, with plant room at roof level, together with all necessary ancillary site works. The extension shall comprise of Emergency Department at Lower Ground Floor level, Endoscopy Unit and link corridor at Ground Floor Level, Inpatient Bed Ward at First Floor Level and Plant Room at Roof Level. It will also include the installation of Photovoltaic Panels on the roof of the existing hospital. The site works will include the provision of a carpark adjacent to the extension comprising 44 car spaces, 5 motorbike spaces and bicycle bay and a carpark comprising 150 parking spaces on the internal access road to the east of the extensionDecision record indexed
To retain and continue with alterations to previously approved planning application for alterations and extensions to their dwelling house; Planning Ref 23/40. Alterations include the omission of the second storey element to the extension to the west, amendments to the single storey extension to the east and associated elevational and layout changesDecision record indexed
To construct a single storey to the east and two storey extension to the west of their existing dwelling, alterations to the existing elevations and layout, alterations to the existing detached domestic garage, alterations to the site entrance, upgrade of the existing wastewater treatment system and percolation area and all associated site worksDecision record indexed
Of alterations to as built development previously approved and constructed under planning reference 04/2348 which includes retention of (a) house position, (b) additional floor area at ground and first floor, (c) alterations to plans/elevations (d) site boundaries, location of as built entrance walls & roadside fence together with RETENTION of existing detached domestic garageDecision record indexed
To erect 1st floor extension over existing single storied, rear entrance lobby and detached domestic garage, to provide additional bedroom, study and storage space to existing dwelling5 conditions indexed
Cavan County Golf Club, Arnmore House Drumelis, Co. Cavan
To construct a 30 metre lattice mobile and broadband tower with headframe carrying telecommunications equipment together with associated equipment and cabinets enclosed within a 2.4m palisade fence compound. Significant further information and revised plans have been submitted.Decision record indexed
To erect a fully serviced part two storey, part single storey dwelling, entrance, boundary walls and piers, waste water treatment facilities, detached domestic garage, and all ancillary worksDecision record indexed
- RED III - for the construction of a single storey geothermal plant building with an associated yard area including access stairs. The Geothermal plant building will house ground source heat pumps and will be connected by buried pipework to a series of geothermal boreholes located to the south of the existing hospital. This Geothermal Plant is set to serve the previously granted Cavan General Hospital extension planning application, Ref-2460276. The application includes all associated boundary treatments, landscaping, and site development works necessary to facilitate the installation and integration of the development within the hospital groundsDecision record indexed
Erect fully serviced storey and half type dwelling with detached domestic garage, sewerage treatment facilities, entrance and all ancillary works8 conditions indexed
To retain alterations to plans, elevations, site layout and all ancillary works of previously approved dwelling (Pl. Ref. No. 19/172)3 conditions indexed
For the development of 7,588sqm accommodation, will comprise the following: 1) New 5 storey extension to accommodate an Emergency Department at Lower Ground Floor, an Endoscopy Unit at Ground Floor, Inpatient Ward Accommodation at First, Second and Third Floor, and Plant area at Fourth Floor 2) A link corridor to connect the proposed extension at ground floor level to the existing hospital at lower ground floor level. 3) External ASHP Compound and Plant 4) Waste Hold 5) Switch room constructed independently to the main build 6) 37 no. car parking spaces (including 10 no. accessible spaces and 4 no. EV charging spaces) 7) 7 no. motorbike spaces 8) All boundary treatments, vehicle and pedestrian accesses, landscaping, and associated site development worksDecision record indexed
For a 1569 sq. m two-storey Enhanced Community Care Hub with plant room at roof level, together with all necessary ancillary site works. The development shall comprise of 25 no. clinical rooms and gymnasium at ground floor level. Ancillary facilities including lobbies, reception, waiting areas, education rooms, admin offices, storerooms, comms room, toilets, staff lounge and staff changing facilities. PV panels and green roof at roof level. 50 no. car parking spaces including 5 no. accessible parking spaces, and one bicycle stand. All boundary treatments, vehicle and pedestrian accesses, landscaping, and associated site development worksDecision record indexed
- RED III - for 2 no. plant compounds which will be ancillary to the Enhanced Community Care Hub which was previously granted planning permission under planning reference 24/60209. The ASHP (Air Source Heat Pump) Compound is proposed at 24m2 and will be located externally at ground floor level. It will comprise 2 no. heat pumps erected on a concrete plinth which will be screened and secured from the surrounding ECC development with palisade fencing. The Substation compound is proposed at 74.4m2 and will be located adjacent to the public car park at lower ground floor level and will comprise a single-storey substation building and an external yard. The Substation building, comprising 41m2 will be constructed to ESB standards and will comprise 1 No. LV Switch room, 1 No. MV Switch room and 1 No. ESB Substation. An external yard of 34.4m2 will be screened and secured from the car park with palisade fencing and will comprise 1 No. LV Generator in sound attenuated enclosure and 1 No. generator oil tankDecision record indexed