For Electrical Infrastructure Upgrade Works on the hospital campus which includes: 2no. new Substations. Substation Building 1 is located to the south west of the site and includes an associated compound and a containerised generator. Substation Building 2 is located to the north of the site and includes an associated compound and a containerised generator. In the location of Substation Building 2 works also include a new water tank, pumphouse, a new oil tank with associated fencing, and a gas compound containing 4no. gas tanks
To erect 8 No. fully serviced dwellings as follows: 2 No. 2 bed semi-detached bungalows, 4 No. 4 bed two storey semi-detached and 2 No. 4 bed two storey detached, all with optional habitable attic accommodation, entrance of existing service road, form service road, public footpath and connection to services and all associated works
For a 5,236 sq. m. three storey extension, with plant room at roof level, together with all necessary ancillary site works. The extension shall comprise of Emergency Department at Lower Ground Floor level, Endoscopy Unit and link corridor at Ground Floor Level, Inpatient Bed Ward at First Floor Level and Plant Room at Roof Level. It will also include the installation of Photovoltaic Panels on the roof of the existing hospital. The site works will include the provision of a carpark adjacent to the extension comprising 44 car spaces, 5 motorbike spaces and bicycle bay and a carpark comprising 150 parking spaces on the internal access road to the east of the extension
To erect a fully serviced part single storey/part two storey dwelling, detached domestic garage, new site entrance, wastewater treatment system, percolation area and all ancillary site works
For alterations to previously approved dwelling (Pl. Ref. No. 22/478), alterations to site layout plan and all ancillary site works
For (1) Retention of change of use from existing Off Licence to Hairdressers (2) Change of use from existing Public House to new stand-alone retail unit at ground floor (3) Change of use from existing Public House and residential area to new retail unit at ground floor comprising of staff facilities, office, toilets, deli, off licence & shop space (4) Change of use from existing residential space at first floor to 2. no 1 bedroom apartments. (5) Alterations to existing elevations, new signage & all ancillary site works
For the construction of a standalone bus shelter and all ancillary site development works
To retain conversion of the attached garage to habitable accommodation. Planning PERMISSION is also being sought to erect a part single storey part two storey extension to the rear of the dwelling, together with all associated site works
- RED III - for the construction of a single storey geothermal plant building with an associated yard area including access stairs. The Geothermal plant building will house ground source heat pumps and will be connected by buried pipework to a series of geothermal boreholes located to the south of the existing hospital. This Geothermal Plant is set to serve the previously granted Cavan General Hospital extension planning application, Ref-2460276. The application includes all associated boundary treatments, landscaping, and site development works necessary to facilitate the installation and integration of the development within the hospital grounds
For single storey domestic extensions, internal alterations, connection to existing onsite services and associated works
To change plots 7 & 8 from previously approved under planning reference 21/213 & ABP case number 310698 from 2no. four bed detached dwelling houses to 2no. four bed semi-detached dwelling houses with associated alterations to site layout and all ancillary works
For the erection of 3 no. fully serviced two storey detached dwellings, form entrances, connection to public services, new service road & entrance and all associated works, significant further information received
For alterations to the previously approved residential development granted under planning application ref. 23/60123. the proposed alterations include (a) omit housetype 1 on site 2 to facilitate a new site entrance to an existing adjacent dwelling, (b) mirror housetype 2 on site 1, (c) alterations to the previously approved site layout plan and all ancillary works
To erect an all-weather multipurpose pitch in replace of existing grassed pitch to include perimeter fencing, flood lighting, changing facilities, handball / activity wall, half basketball court and all associated works
For the development of 7,588sqm accommodation, will comprise the following: 1) New 5 storey extension to accommodate an Emergency Department at Lower Ground Floor, an Endoscopy Unit at Ground Floor, Inpatient Ward Accommodation at First, Second and Third Floor, and Plant area at Fourth Floor 2) A link corridor to connect the proposed extension at ground floor level to the existing hospital at lower ground floor level. 3) External ASHP Compound and Plant 4) Waste Hold 5) Switch room constructed independently to the main build 6) 37 no. car parking spaces (including 10 no. accessible spaces and 4 no. EV charging spaces) 7) 7 no. motorbike spaces 8) All boundary treatments, vehicle and pedestrian accesses, landscaping, and associated site development works
For a new detached domestic car garage to the rear of the property along with a temporary access gate, also RETENTION sought for 2 no. permanent extensions for domestic purposes to the rear each attached to the existing dwelling together with all associated site services
For temporary permission for 5-years for development on lands at Block 3, Drumalee Health Campus, Cootehill Road, Drumalee Cross, Co. Cavan. The proposed development consists of a medical CT and MRI scanning facility in a single storey U-shaped, aluminium clad prefabricated building with a central gated courtyard utility space. The building includes reception area, consultation room, changing areas, toilet, control rooms, scanning rooms, and plant areas. An ESB substation and switchroom are also proposed in a separate single storey building adjoining the site entrance. The development includes all associated site works and services.
To construct a new single storey extension to the front of existing dwelling house, together with all associated site development works
For relocating the existing entrance and front boundary walls with new entrance walls, piers and all associated site works
To retain existing concrete slab and erect Domestic Garage over same and all associated works
For a 1569 sq. m two-storey Enhanced Community Care Hub with plant room at roof level, together with all necessary ancillary site works. The development shall comprise of 25 no. clinical rooms and gymnasium at ground floor level. Ancillary facilities including lobbies, reception, waiting areas, education rooms, admin offices, storerooms, comms room, toilets, staff lounge and staff changing facilities. PV panels and green roof at roof level. 50 no. car parking spaces including 5 no. accessible parking spaces, and one bicycle stand. All boundary treatments, vehicle and pedestrian accesses, landscaping, and associated site development works
- RED III - for 2 no. plant compounds which will be ancillary to the Enhanced Community Care Hub which was previously granted planning permission under planning reference 24/60209. The ASHP (Air Source Heat Pump) Compound is proposed at 24m2 and will be located externally at ground floor level. It will comprise 2 no. heat pumps erected on a concrete plinth which will be screened and secured from the surrounding ECC development with palisade fencing. The Substation compound is proposed at 74.4m2 and will be located adjacent to the public car park at lower ground floor level and will comprise a single-storey substation building and an external yard. The Substation building, comprising 41m2 will be constructed to ESB standards and will comprise 1 No. LV Switch room, 1 No. MV Switch room and 1 No. ESB Substation. An external yard of 34.4m2 will be screened and secured from the car park with palisade fencing and will comprise 1 No. LV Generator in sound attenuated enclosure and 1 No. generator oil tank
To retain existing fully serviced two-storey extension to existing dwelling and all associated works
Of: (A) Erection of canopy structure with signage above existing ground floor entrance door. (B) Install fibre cement cladding finish to existing external lift shaft & proposed canopy structure along with alterations to existing elevations. (C) Alterations to existing carpark layout, provision of EV charging points and colour coded designated parking spaces. (D) Installation of raised planters, hard landscaping and all associated site works
Of the following, 1) Retain & complete partially constructed detached storage shed & 2) Retain domestic detached timber cabin ancillary to the existing dwelling
For: (a) Change of use of 1no. ground floor retail unit & first floor stockroom & administration area in Block 1 to healthcare use, (b) Change of use of 2no. ground floor retail units & 2nd floor administration area in Block 2 to healthcare use, (c) minor alterations & increased area of first floor link corridor between blocks 1 &2, (d) Provision of 2no. EV charging in lower ground floor, associated alterations to elevations, signage and all ancillary works
Sought to (a) RETAIN single storey ground floor extension to rear of existing dwelling and (b) PERMISSION to construct a first-floor extension to rear of existing dwelling and all ancillary site works
To retain ground floor and second storey extension to existing uninhabitable garage, alterations to plans, elevations and all ancillary site works
For (1) erection of a two storey extension to the front of the existing dwelling (2) conversion of existing attic to form habitable space (3) alterations to existing floor plans & elevations (4) all ancillary site works
Of: (1) demolish existing single storey rear extension and erect part single storey and part two storey extension to the side & rear of existing dwelling, (2) replace existing roof and form habitable first floor accommodation within the roof space, (3) alterations to the existing building layout and elevations, (4) erection of detached Domestic Store, (5) all ancillary site works
To retain changes made to garage to include: addition of windows, location of windows and door, increase in floor area and mirroring of structure during construction, previous Pl. Ref. No. 99/1098
To RETAIN development at Swellan Upper, Cavan, Co. Cavan consisting of the adaption of the existing dwelling house to a dwelling house with ancillary granny flat and associated elevational changes. Planning permission is also sought to carry out further alterations to the dwelling and granny flat
To erect single storey extension to rear of existing dwelling, connection to all existing services, all associated and ancillary works
To erect fully serviced single storey extensions to side of existing dwelling with associated alterations to elevations, new detached domestic garage & all ancillary works
To retain domestic garage constructed to DPC level and PERMISSION to complete
To decommission existing sewerage treatment unit and percolation area and install new sewerage treatment unit and percolation area
To demolish single storey extension to rear of existing dwelling and replace with new single storey extension, associated alterations to elevations, connection to existing services, reduce levels of rear garden and all associated and ancillary works. PERMISSION also sought to convert existing detached domestic garage to self-contained annex for family member only
To convert existing bungalow to dormer dwelling providing additional first floor with increased roof height, demolish existing extension to rear of dwelling, alterations to plans/elevations of existing dwelling, construct pitched roof to existing flat roof attached garage and associated site works
EXTENSION OF DURATION of 19/472 to erect 6 no. Storey & a half style (Detached 5-bed dwellings) together with entrances, footpath, connect to existing foul sewer, surface water sewer, water main, landscaping, boundary treatments and all associated works, Significant further information and revised plans have been submitted
For alterations to finished floor levels and site levels of houses 1-6 (6 no. two-storey 5-bedroom detached dwellings) previously approved under Pl. Ref. 19/472 and extended under Pl. Ref. 25/37 and all associated works
To erect 6 no. Storey & a half style (Detached 5-bed dwellings) together with entrances, footpath, connect to existing foul sewer, surface water sewer, water main, landscaping, boundary treatments and all associated works, Significant further information and revised plans have been submitted
To erect a fully serviced storage extension to side of existing waste handling unit (waste permit WFP-CN-21-0003-01 relates to this facility) and all ancillary site works
Of development from previously granted planning reference no.s 17/467 & 15/142 to consist of: (1) retention of alterations to office extension (2) retention of ESB substation and associated plant (3) retention of Rainwater harvesting tanks and associated infrastructure (4) retention of alterations to parking areas, landscaping and all associated and ancillary works
Alter site boundaries with associated alterations to house position to previously approved Planning Reg No 19/189
To alter location of previously approved attenuation tank (Pl. Ref. 11/326) and all associated works
For • RETENTION of a single storey extension to side of existing dwelling incorporating additional living accommodation and attached domestic garage with associated alterations to floor plans and elevations of previously approved application ref: 647245. • RETENTION of alterations to site layout, site boundaries, entrance and all ancillary works. PERMISSION is also sought for: • Alterations to site layout and site boundaries, new sewerage treatment unit and percolation area and all associated and ancillary works
To erect 2 no. fully serviced 3 storey split level detached dwellings with attached domestic garage, entrances, connection to foul sewer an watermain and all ancillary works
For the development of constructing 2 No. 2-Bedroom Bungalows. Connection to all existing services, new entrances, landscaping and all associated site works
To construct a 30 metre lattice mobile and broadband tower with headframe carrying telecommunications equipment together with associated equipment and cabinets enclosed within a 2.4m palisade fence compound. Significant further information and revised plans have been submitted.
Demolish 2 no. existing domestic garages, excavate existing embankment and erect retaining wall, alterations to site boundaries and all ancillary works. Significant further information and revised plans have been submitted