Showing 1-4 of 4 public recordsPERMISSION & RETENTION: The development will consist/consists of: Amendments to development granted under Reg. Ref. 4658/18, as amended by Reg. Ref. 4603/19 and Reg. Ref. 3027/20 as follows: Retention permission for alterations to the south-east corner of the building comprising a small setback recess at the corner at all floors and relocation of permitted green wall, and retention of the reconfiguration of piling on the eastern boundary and south-west corner of the basement levels. Planning permission to remove a permitted sedum roof at roof level and replacement with additional PV panels, an additional plant area, amendments to the permitted plant area and an increase in height of the lift overrun. Planning permission for an increase in height of the substation at the northeast corner of the site by 0.9m and other minor amendments. Planning permission for the provision of a triangular powder-coated finish totem sign to the south-west corner of the site and signage on the western and southern elevations. General alterations at basement and lower ground floor to include minor alterations to the room layout, the inclusion of an e-scooter charging station, reconfiguration of motorcycle parking, and changing one wheelchair accessible parking space to a non-wheelchair accessible space and all associated works. The adjoining building at 32 Merrion Road is a Protected Structure.
The development will consist of the amendment of previous permission Reg. Ref: 4658/18, as amended by Reg. Ref: 4603/19 and Reg. Ref: 3027/20 as follows: The addition of an additional floor over approved four storey front block facing Merrion Road which will increase building height at this point from four storeys to five storeys and 17.3m to 21.125m. The addition of an additional floor over the approved six storey rear block and building core which will increase overall building height from six to seven storeys and from 25.1m to 28.925m. Minor changes to the internal layout resulting from the additional floors, and all other ancillary works. The proposed modifications will result in an overall GIA increase from 10,531m2 to 11,781m2 for the proposed development. The proposals are adjacent to a Protected Structure.
The development consists of the amendment of previous permission Reg. Ref. 4658/18, as amended by Reg. Ref. 4603/19, as follows: 1. Relocation and reconfiguration of substation and switchroom from the north west corner of the site to the north east corner in a two storey structure; 2. Relocation of plant to a screened area at roof level; 3. Relocation of the cycle lift to a new external structure to the east of the building. A fire stair is also proposed within this structure; 4. Enlargement of basement by 135m2 at both basement level -1 and basement level -2 (a total increase of 270m2); 5. Exterior wall thickness increased by 275mm to accommodate precast concrete panels; 6. Alterations to the atrium and core at all levels and resulting in the reduction in the café/restaurant from 178m2 to 164m2 at ground floor level; 7. Minor alterations to the layout at all floors including basement level -1 and -2; and 8. Minor alterations to the elevations, landscaping plans at ground and terrace level and all other associated works. Surface car parking is reduced from three spaces to two. Basement level -1 car parking is reduced from 40 to 39. The proposals are adjacent to a Protected Structure.
The development consists of the amendment of previous permission (Reg. Ref. 4658/18) as follows: 1. Re-configuration and relocation of core within the permitted envelope to increase usable space at all levels. 2. Enlargement of the basement at Levels -1 and -2 resulting in: Removal of restaurant space and car parking from Basement Level -1. Increase in office space to 1,118m2, the provision of a gym (181m2), locker, changing and shower facilities and cycle parking at Basement Level -1; Enlargement and re-configuration of Basement Level -2 to provide 40 car parking spaces. 3. Overall alterations to the car and cycle parking provision to provide 43 car parking spaces (40 at Basement Level -2 and 3 spaces at ground level), an increase of 5 spaces; and 134 cycle parking spaces (100 at Basement Level -1 and 34 visitor spaces in the curtilage), an increase of 18 spaces;. 4. Introduction of lightwells to provide light to enlarged basement; 5. Provision of cafe/restaurant and office breakout space at ground floor in place of approved restaurant at ground floor and Basement Level -1 and reception area at ground floor; 6. Provision of free standing glass pods on 4th floor terrace to provide informal meeting areas; 7. Alterations to internal plant space and provision of external plant space; 8. The facade is proposed to be polished concrete; 9. Switch room to approved substation; 10. And all other associated works. Minor alterations are proposed to the elevations; the building height and dimensions remain as permitted. The proposals are adjacent to a Protected Structure.