Planning records
Showing 1-3 of 3 public recordsPROTECTED STRUCTURE: No. 91 Camden Street Lower, Dublin 2 which is a protected structure, RPS. 1159. At the rear there are two returns and a yard linked by right of way to the street at Camden Row. The development consists of: (a) At Roof Level: taking down and re-building existing chimney stack, rebuilding the existing original brick chimney and construction of new DPC where stack breaks the roof slope to prevent falling damp, re-using the existing bricks and clay pots, with a new lime mortar flaunched capping. (b) At Ground Floor Level - Change of use from retail/deli to cafe/restaurant (c. 86.9 sq.m) including: removal of existing floor slab and replacement with a limecrete insulated slab, careful refurbishment of cast-iron columns and downstand beams and application of intumescent fire proofing protection to metal structure to comply with fire officers requirements, careful refurbishment and repair of period meat carcass hanging systems and T&G timber wall linings, provision of a new glazed corridor to allow for dual access to the café/restaurant and protected stairs to upper floors. Removal of non-original internal stairs to the rear return and rebuilding of compliant stairs in same location, provision of external seating area to the rear for use with proposed café/ restaurant (22.4 sq.m). (c) At First Floor Level - Change of use from retail/office to café/restaurant (c. 87.0 sq.m) including: two existing rooms to the main building from office/retail use to café seating and lobby. To the two rear return: two existing rooms to use as visitor restrooms, staff facilities, kitchen and ancillary space/uses associated with the cafe / restaurant. Removal of non-original internal stairs to the rear return and rebuilding of compliant stairs in same location. (d) At Second Floor Level - Change of use from office associated with the retail/deli use to art gallery use (c. 52.7 sq.m). (e) At Attic Level, restoration of historic cruciform oak-beam roof structure to main building and reinstatement of timber sheeting to the underside of sloped roof, removal of 7.5 sq.m of non-original timber ceiling joists to provide a double height space to the art gallery, allowing a better internal appreciation of restored cruciform roof. (f) Externally to the Front Elevation: restoration and repair of Dutch Billy front gable and wall façade including removal of non-original sand/cement render and replacement with breathable lime render. To the Ground Floor Shopfront: careful restoration of historic features including awning refurbishment and reinstatement, removal of non-original stainless steel vent over length of shopfront, refurbishment of existing front door, addition of vertical mullions and servery hatch in shopfront, replacement of existing glazing with histo-glass type or similar approved 'thin' double glazing. Restoration of sliding sash windows to the front façade first and second floors, with historically correct 6 over 6 pane of with histo-glass type or similar approved 'thin' double glazing, removal of modern poor quality timber windows to rear façade and replacement with historically correct 4 over 4 pane of with histo- glass type or similar approved 'thin' double glazing, replacement of existing attic window to rear with historically correct vertical sliding timber sash window. Careful restoration and repair of original lunette window to front façade at attic level. Removal of existing modern gate to rear courtyard area and construction of painted mild steel gate and side panels with a contemporary design, etched and painted, between café external seating space and abattoir area to No. 3 Camden Row. Removal of existing services and replacement with new energy efficient services including UV filtration system extract to rear return. All associated refurbishment works to the interior and exterior: Completion of repairs and renovation of historic/modern fabric as detailed in the Conservation Methodology Statement in compliance with Conservation Best Practice. Together with all associated and ancillary works to those described above.
RETENTION & PERMISSION: PROTECTED STRUCTURE: Retention permission for development on lands (c.0.256ha) at Nos. 1, 2, 3, 4 and 5 Camden Street Upper and Nos. 49, 50 and 51 Camden Street Lower and all associated sites to the rear addressing Grantham Place, Dublin 2 (including 12 Grantham Place). Nos. 1, 2, 3, 4 and 5 Camden Street Upper and Nos. 50 and 51 Camden Street Lower are Protected Structures. The development for retention consists of modifications to development previously permitted under Reg. Ref. 2045/16 (PL29S.247635) at the above address. The modifications for retention permission consists of: (a) Alterations at Lower Ground Floor Level to include removal of 6 no. guest bedrooms at lower ground floor of 1-5 Camden Street Upper and 50-51 (Camden Street Lower) to be replaced with staff and other hotel facilities; staff facilities altered to maintenance stores and general store changed to staff room; new openings to courtyard from atrium/ link at lower ground floor level; 2 no. guest bedrooms relocated from lower ground floor of atrium/ link building and replaced with approx. 109sqm of function space/ meeting room separated from main customer area by screen doors; new plant area added at Lower Ground Floor of No. 51 (Camden Street Lower) to replace 1 of 6 no. hotel bedrooms; new sprinkler tank with green living wall screen added to courtyard to rear of 51 Camden Street Lower for fire safety of atrium design and No. 5 Camden Street Upper; Internal layout changes to new build at Lower Ground Floor to the rear at Grantham Place including new stair layout to ground floor level and new fire escape stair to the rear; (b) Alterations at ground floor level to include minor amendments to internal opening between front and rear reception at No. 5 Camden Street Upper; facade altered from render to original restored and repointed brick (at all levels); amendments to materials at entrance to No. 49; revised atrium design to include new link structure; 2 no. bedrooms relocated from Lower Ground Floor Level to replace customer areas at rear of No. 50 and 51 Camden Street Lower; new fire escape stair exit to the rear at Grantham Place and associated alterations to rear elevation at Grantham Place including revised railing treatment; canopy roof omitted within courtyard; hotel reception moved from rear of No. 4 to front of No. 5 Camden Street Upper; luggage room moved from No. 5 to No. 4 Camden Street Upper; residents lounge/ waiting area moved from front to rear of No. 5 Camden Street Upper; windows at ground floor of chapel annex blocked up for fire safety purposes; and other related fire safety and internal layout improvements within new build element to the rear; (c) Alterations at First Floor Level to include revised layout to hotel bedroom at No. 5 Camden Street Upper including new bathroom location; new sprinkler system added to rooms 111 and 112 for fire safety purposes; glass roof changed to solid roof at fire exit to north side of chapel annex; alteration to atrium design and internal walkway; relocation of internal stair within chapel to rear; additional openings added to chapel for structural stability; and infill of recess between chapel and new hotel block to the rear at Grantham Place; (d) Alterations at Second Floor Level to include alteration to hotel bedroom at No. 5 Camden Street Upper including new bathroom location; new sprinkler system added to rooms 211 and 212 for fire safety purposes; and other alterations as undertaken at lower levels including revised atrium design and recess infill; (e) Alterations at roof level to include pitched roof design at atrium and recess infill between chapel and new hotel block at Grantham Place; and (f) Permission is also sought for landscaping and all ancillary and associated site development works for the alterations described. The proposed changes will result in a reduction in the number of hotel bedrooms from 98 to 89 in total.
PROTECTED STRUCTURE: RETENTION: Retention planning permission is sought for continuation of lapsed permitted use (planning register reference 2190/12) for change of use of ground and basement and retention of use of first, second and third floors from commercial office space to childcare facility.