Conditional grantDecided 12 March 2021Carlow County Council

20123: To demolish existing single storey dwelling and remove existing septic tank and shed, and construct a replacement single storey dwelling, revisions to existing entrance, new waste treatment system and percolation area, use of on-site mains water and all associated site works

Ballycarney, Co. Carlow
DecisionConditional grant
Decided12 March 2021
Application typePERMISSION
Source documents4

Site

What is on file

0refusal reasons15conditions8nearby records

Decision details

Core application dates and identifiers from the public planning record.

Planning analysis

Refusal reasons and planning conditions extracted from the public decision file.

Refusal reasons

No refusal reason

No refusal reason is on record for this application yet.

Conditions

  • 1Development must be carried out in accordance with plans received 14 April 2020, 20 Oct 2020, and 23 Feb 2021, save as amended by conditions.Compliance
  • 2External walls: render finish and natural limestone, neutral colours. Roof: blue/black slate with matching ridge.Design Materials
  • 3Splayed entrance/sightlines per drawings. One vehicular entrance only. Existing boundary wall removed, new boundary planted with native hedgerow/beech. Aco-drain at entrance mouth. Surface water contained onsite. Soakaways per BRE Digest 365.Traffic Access
  • 4No felling or uprooting of trees without a felling licence under the Forestry Act, 2014.Environment Ecology
  • 5Retain/reinforce side hedgerows. Plant native hedgerow/beech at new boundary. Set back/replace adjacent hedge. Landscaping in first planting season. Replace dead/damaged plants within 3 years.Landscaping Boundary
  • 6Surface water runoff disposed of onsite. Soakaways per BS8301 and BRE Digest 365. Gutters/RWP located to discharge within site.Wastewater Drainage
  • 7Submit Waste Management Plan for agreement (EWC codes, reuse, removal, destinations, soil, hazardous, concrete, contaminated, by-products, segregation, permits). All ESB/telecom services underground. Relocate existing poles at applicant's expense.Construction Management
  • 8Consult Chief Fire Officer and strictly comply with fire safety requirements prior to commencement.Compliance
  • 9Surface water to new soakaways within curtilage. Only clean water to soakaways per BRE Digest 365/BS8301. Soil polishing filter min 45m2. Min one flush out valve. EPA Code of Practice 2009 compliance. Service contract required. Certificate of Compliance within 3 months of occupation with as-constructed drawings. Septic tank tested per I.S. EN 12566/S.R. 66. No surface water infiltration. Grease trap installed.Wastewater Drainage
  • 10Sign Irish Water connection agreement prior to commencement. Obtain approval for build over/divert. Comply with CDS Technical Documentation. Adhere to separation distances. Connections subject to Capital Investment Programme.Water Services
  • 11Pay development contribution of €1,599.45 prior to commencement. 5% p.a. interest applies from decision date to payment date (first 90 days discounted).Development Contribution
  • 12Noise/vibration limited to BS 5228-1:2009+A1:2014 and BS 5228-2:2009+A1:2014. Dust levels <350 mm/m2/day per VDI 2119.Construction Management

Source documents

Original council portal records and source PDFs where available.

Nearby precedent