RefusedDecided 10 September 2024Carlow County Council

Belmount, Red Bog Tinahely, Wicklow

Planning application 2460071
DecisionRefused
Decided10 September 2024
Application typePERMISSION
Source documents5

Site

What is on file

0refusal reasons18conditions8nearby records

Proposed development

Application description published by Carlow County Council.
The construction of a Single-Storey Dwelling, septic tank & percolation area, bored well, splayed entrance and all associated site development works

Application and appeal history

Structured appeal stages, outcomes and source documents currently tied to this application.

No indexed appeal history

No structured appeal case is tied to this application. This means no appeal is indexed, not that an appeal is impossible.

Decision details

Core application dates and identifiers from the public planning record.

Planning analysis

Refusal reasons and planning conditions extracted from the public decision file.

Refusal reasons

Refusal reasons not machine-readable

Refusal reasons were not machine-readable from the source documents. See the source PDFs below.

Conditions

  • 1Disconnect existing mobile home from existing well and septic tank prior to occupation.Occupancy
  • 2Decommission, pump out and fill existing septic tank with hardcore prior to occupation.Wastewater Drainage
  • 3Divert only clean surface water to soakaways within site boundary.Water Services
  • 4Design and install soakaways per BRE Digest 365.Water Services
  • 5Install vents at ends of percolation pipes.Wastewater Drainage
  • 6Limit distribution pipes to max 6 from a single box.Wastewater Drainage
  • 7All percolation pipes must originate from the distribution box.Wastewater Drainage
  • 8Fit pipe seals on distribution pipes and liquid levelling devices on percolation pipes.Wastewater Drainage
  • 9Install activated carbon filters on vent pipes; replenish bi-annually.Wastewater Drainage
  • 10Design, construct, operate and maintain system per EPA Code of Practice (PE ≤ 10) 2021.Wastewater Drainage
  • 11Submit Certificate of Compliance with as-constructed drawings prior to occupation.Compliance
  • 12Certify septic tank tested per I.S. EN 12566.Compliance

Planning a project near Belmount, Red Bog Tinahely, Wicklow?

Get a site risk brief with the local decision pattern and up to 80 detailed nearby comparables (40 refusals and 40 grants), including extracted reasons and source links. €29 incl. VAT, PDF by email.

Source documents

Original council portal records and source PDFs where available.

Nearby precedent

Similar nearby applications linked to this planning decision.
Get up to 80 detailed nearby comparables in a site risk brief →