GrantedDecided 13 May 2025Carlow County Council

Paulville, Tankardstown, Tullow

Planning application 2460369
DecisionConditional grant
Decided13 May 2025
Application typePERMISSION
Source documents6

Site

What is on file

0refusal reasons14conditions8nearby records

Proposed development

Application description published by Carlow County Council.
Is sought for renovation and extension of existing dwelling and all associated site works

Application and appeal history

Structured appeal stages, outcomes and source documents currently tied to this application.

No indexed appeal history

No structured appeal case is tied to this application. This means no appeal is indexed, not that an appeal is impossible.

Decision details

Core application dates and identifiers from the public planning record.

Planning analysis

Refusal reasons and planning conditions extracted from the public decision file.

Refusal reasons

No refusal reason on record

No refusal reason is on record for this application yet.

Conditions

  • 1Development carried out in accordance with plans received 20/11/2024, amended by FI 13/04/2025.Compliance
  • 2Permission authorises development as described in public notices and plans received; does not relate to other development on site.Compliance
  • 3External walls, roof and window finishes per Drawing Ref. RFI 01/03 (13/04/2025).Design Materials
  • 4Landscaping/planting retained/maintained per Landscape Site Plan (13/04/2025). Native species. Hedgerow along realigned roadside boundary min 4-5 years growth. New planting completed within first planting season following construction.Landscaping Boundary
  • 5Sightlines at entrance to public road per Sightlines Site Plan (RFI 02/03, 13/04/2025) and DMRB. Roadside verge kept free from obstruction. Road opening works subject to Road Opening Licence. Do not interfere with public road without consulting Municipal Engineer.Traffic Access
  • 6On-site domestic wastewater treatment system and percolation area/polishing filter designed, constructed, operated, maintained per EPA Code of Practice (PE ≤ 10) 2021. Certificate of Compliance prior to 1st occupation. Septic tank tested per I.S. EN 12566. Vents at ends of percolation pipes. Max 6 distribution pipes from single box. Percolation pipes originate from distribution box. Pipe seal on distribution pipes, liquid levelling device on percolation pipes. Percolation area min 10m from dwelling, septic tank min 7m from dwelling. No surface water infiltration. Domestic grease trap installed.Wastewater Drainage
  • 7No surface water runoff to adjoining public road/properties. Surface water collected and disposed to soakaways/surface water system on site per B.S. 8301:1985 and BRE Digest 365 with inspection manhole covers. Only clean surface water to soakaways. Foul waste to on-site wastewater system.Wastewater Drainage
  • 8Material removed from site recovered/disposed at licensed facilities by licensed operators.Environment Ecology
  • 9Construction phase: off carriageway parking for all traffic. No parking/storage along public road. Prevent muck/dirt/debris on public road. Site neat and litter free. Waste disposal skips on site. Noise/dust emissions not impair amenities. No materials on public road/footpath without consent. Do not interfere with public road/footpath without consulting Municipal District Engineer.Construction Management
  • 10Construction hours: Mon-Fri 08.00-18.00, Sat 08.00-13.00. No Sundays/Bank Holidays. Deviation only with prior written approval.Construction Management
  • 11Consult Chief Fire Officer prior to commencement, comply with fire safety requirements.Compliance
  • 12Connect to public water/wastewater network: sign agreement with Uisce Éireann prior to commencement. Comply with Uisce Éireann documentation. If existing connection impact significant, new/revised agreement required. Connections subject to Uisce Éireann Capital Investment Programme constraints.Water Services

Planning a project near Paulville, Tankardstown, Tullow?

Get a site risk brief with the local decision pattern and up to 80 detailed nearby comparables (40 refusals and 40 grants), including extracted reasons and source links. €29 incl. VAT, PDF by email.

Source documents

Original council portal records and source PDFs where available.

Nearby precedent

Similar nearby applications linked to this planning decision.
Get up to 80 detailed nearby comparables in a site risk brief →