Demolition of the single-storey flat-roof extension and front wall with gate to the side of existing dwelling. Construction of a new two storey, three-bedroom pitched-roof dwelling with shared vehicular access and off-street parking from Monastery Drive, connection to public services, and all associated site development works.
1) External insulation to front and gable with smooth render finish. 2) Porch overhang to front. 3) Removal of window to front to incorporate increased entrance size and reduced window size to front. 4) Increased dormer size and modified design with parapet to gable end to rear. 5) All associated site works and drainage connections.
1 industrial storage building to the west of the main complex with an area of 465.3sq.m and a height of 8.8m; all associated site works and utility connections.
Permission is sought for construction of a bedroom extension at first floor level to the side of existing house. Alterations to elevations and internal layout. 6 No. of roof lights. Relocation of existing front door, garage conversation and all associated site development works at no. 11 Monastery Crescent, Clondalkin, Dublin 22, D22 K199.
The removal of the original lean-to porch roof & the addition of a single storey flat roof extension of c. 9 sq.m to the front (South) of the property. All internal & elevation alterations with 3 associated roof lights. The development will also include for the alteration of the original pedestrian access to the side (West) boundary & all associated site development & ancillary works.
Planning permission sough for 8 square meter single story extension to front with pitched roof for new entrance and extended living room.
Planning permission sought for the construction of a first floor extension over existing single storey extension to front, side and rear of existing house, additional first floor extension consisting of proposed bedroom with dormer window to front and rear roofs and all associated site works.
Proposed roof light on front slope of roof at first floor level.
Erection of a first floor bedroom extension above the existing garage; raise section of the tiled roof to match the existing roof; front of the extension will have a dormer type roof with two windows to the front; convert the existing garage to a study and relocate the front door.
2 industrial storage buildings to the west of the main complex; Building no. 1 - 460sq.m with a height of 8.8m; Building no. 2 - 244.4sq.m with a height of 7.0m; all associated site works and utility connections.
The development consists of a first-floor extension to the side, a dormer roof and roof light to the front, a ground-floor extension to the rear, reconfiguration of ground and first floor plan layouts, a dormer roof to the rear, and all ancillary works necessary to facilitate the development.
Retention Permission for conversion of the existing garage to habitable space, A side extension at first floor level with double-pitched roof continuing the existing main roof profile and a front dormer window similar to the existing front dormer window. Permission for removal of the existing chimney, A front extension at first floor level with double-pitched roof. A flat-roofed ground floor level extension to the rear and a flat-roofed dormer extension to the rear.
Construction of a new two storey house adjacent to the existing house; a new driveway to the front; new garden access gates to the side and all associated site works.
(a) Demolition of existing rear single storey extension and construction of a new rear single storey flat roof extension in lieu; (b) construction of new dormer to rear in lieu of existing dormer; (c) internal alterations to existing dwelling to create a self-contained family unit accessed from main house; (d) construction of a new front porch extension with flat roof; (e) all associated site works.
Construction of a single storey flat roof and double pitch slope roof extension to the rear of existing dwelling; Internal & Elevational alterations to the existing house; New off-street parking; New landscaping, boundary fencing, drainage and associated site works
This development will consist of the following works to the existing generator compound located at the north of the site: (1) the change of use from a generator compound to an enclosed bicycle store, (2) replacing the existing metal grate roof with a new single skin non-drip flat roof; to cover 24 secure bicycle store spaces and 3 electric scooter spaces.
Change of use of the existing building on site (comprising 763sq.m gross floor area) from office use to light industrial use (comprising the assembly of hampers and online orders at first floor area, digital device repair and refurbishment at second floor level with ancillary staff canteen and reception area at ground floor level); The development also includes the provision of a bicycle store (6 spaces) at ground I undercroft level, along with all ancillary works.
The construction of a single storey building to be used for Physiotherapy. Access/egress from the proposed development is via the existing club entrance on Monastery Road, Clondalkin, Dublin 22.
Erection of a perimeter steel fence to match existing fence as erected on neighbouring property 2.5m high and the installation of a new electronically controlled entrance gate set back approx. 13m from road side 2.1m high.
Permission and permission for retention for an existing rear extension to the house, existing pitched roof over the rear extension and side of the house, existing window to the front elevation, and replacement and relocation of the existing main entrance door with a new entrance door and associated side panels to the front elevation.
A self-storage facility (for a temporary period of three years) comprising 40 no. 20 foot long shipping containers (14 sq.m. each)
Alteration to the front domestic south facing elevation consisting of 17sq.m of PV solar panels located on the existing house front roof pitch; alterations to first floor front bedroom windows ope to contain a central self-coloured acrylic render external insulated system on masonry wall to create new window elevational layout; alterations extending beyond the front building line of the domestic south facing elevation consisting of new self-coloured acrylic render external insulated system to ground and first floor level and grey brick slip finish to external insulated system to ground floor bay window walls.
The development will consist of: The erection of two No. illuminated signs on the west and south facade of the existing building known as block 20 and all assocated site works.
Single storey outbuilding in the rear garden, which is a revision to the garage previously granted under An Bord Pleanala Ref. No. PL06S.247883 and all ancillary site works.
The development comprises the retention of the following amendments to the development permitted under Reg. Ref.: SD20A/0309, as amended by Reg. Ref.: SD22A/0093 and Reg. Ref.: SD23A/0158, which arose during the detailed design / construction stage of the project: Amendments at plant and roof level including the reconfiguration of plant and associated extracts, provision of a roof level package plantroom, provision of 2 no. backup landlord generators, reconfigured gantry associated with the 2 no. back-up landlord generators, and reconfiguration of solar PV panels; The provision of 2 no. pumproom buildings to accommodate process water and fire water with a gross floor area (GFA) of c. 44 sq.m and c. 105 sq.m; The provision of underground water process tanks located to the south of ICT Facility 1; The provision of a wastewater treatment skid located to the west of ICT Facility 1; Reconfiguration of car parking spaces resulting in an overall reduction of 1 no. car parking spaces from 44 no. car parking spaces to 43 no. car parking spaces; Relocation of permitted cycle parking from the north of ICT Facility 1 to the south of ICT Facility 1; Amendments to fenestration and arrangement of façade treatment to ICT Facility 1 and minor reconfiguration of the internal layout; and All associated and ancillary works. An EPA-Industrial Emissions Directive (IE) licence is required to facilitate the operation of the development.
The demolition of existing single storey side shed and the construction of detached two storey (two bed) dwelling to the side of existing house with amended landscaping, additional vehicular access to serve the new house onto Monastery Walk & new boundaries and site works.
Demolition of existing garage and construction of new 2 storey side extension; demolition of rear conservatory and construction of new canopy; construction of new dormer structure to rear; construction of 2 new dormer windows to front elevation; internal alterations to floor layouts; construction of new front porch canopy and all associated site works.
Alterations to approved development Reg. Ref. SD17A/0291 (An Bord Pleanala Ref. ABP-301369-18) comprising: Retention of (i) deletion of a service room to the rear of the ground floor; (ii) minor extension of bedroom 1 of apartment No. 8 (located on the first floor) by 4.5sq.m. and reconfiguration of associated balcony; (iii) provision of 2 additional one bedroom units and new plant room at ground floor level to the rear of the building; Permission is sought for (i) minor extension of the living room and bedroom 1 of apartment No. 21 (located on the third floor) by 7sq.m and reduction of associated balcony by 7.1sq.m; (ii) amendments to previously approved boundary treatment to provide for a rendered wall with capping stones along Monastery Road; (iii) alteration of approved car parking to provide 5 additional car parking spaces resulting in a total of 29 car parking spaces; (iv) amendments to the approved site layout to facilitate the re-location and addition of bicycle parking spaces to provide a total of 36 bicycle spaces to the western boundary and re-location of bin store from the western boundary to the northern boundary of the site; (v) all ancillary works necessary to facilitate the development.
Conversion of attic space comprising of modification of existing roof structure, new access stairs from first floor and flat roof dormer to the rear.
Remove existing roof on single storey extension to rear of existing dwelling; demolish garage in rear garden; erect single storey granny flat in rear garden and re-roof existing single storey extension to rear; all ancillary site works.
Construction of a new bus interchange to replace that existing at Red Cow Luas park and ride car park. The proposed works consist of the provision of 9 new sawtooth type bus bays, bus shelters, overhead canopies, a bicycle building, passenger and driver welfare facilities, and an electrical substation. A new carriageway arrangement for bus access and circulation including a reconfiguration of the western car park layout to allow for provision of taxi and drop off facilities is also proposed. The proposed works also include minor realignment of the park and ride access road between the mini roundabout entrance to the western car park and the mini roundabout entrance to the eastern car park. The existing Luas stop, depot building, surface parking facilities and bus interchange were originally granted permission under LRO 59 of 1999.
Demolition of existing single storey cottage known as Floraville Cottage; construction of a three storey with setback fourth storey apartment block comprising of 4 one bedroom and six two bedroom apartments each served by private amenity space in the form of balconies and a communal roof terrace at fourth storey level; provision of 6 vehicular parking spaces; 28 bicycle parking spaces and covered bin storage all located within a shared access yard at ground level; removal of existing vehicular access via Monastery Road with pedestrian/vehicular access to the apartment building to be provided via the residential scheme approved under Reg. Ref. SD17A/0291 to the immediate east; all ancillary works inclusive of boundary treatment, lighting, landscaping and SuDS drainage, necessary to facilitate the development.
Removal of Condition No's 2 and 6 of Reg. Ref. SD18A/0289: operational times of the weight and fitness training building to be from 06.00 hours to 22.00 hours Monday to Friday and 8.00 hours to 21.30 hours Saturday and Sunday.
The development will consist of the change of use of the ground, first and second floors from class 3 office use to class 8 for use as a health centre / clinic along with all associated works.
Internal reconfiguration and first floor internal extension (98.36sqm) to the existing light industrial unit (total gross floor area of building increases from 1003.9sqm to 1102.26sqm) and change of use to accommodate warehousing / distribution, professional trade support and training services, showroom for display and sale of painting products, ancillary offices and all associated staff accommodation. Permission is sought for revisions to the existing parking and servicing / delivery areas within the site via existing vehicular entrances from Elm Road and Chestnut Road, minor changes to the southern elevation, new building mounted signage and all associated site and development works associated with the above.
The Erection of a first Floor, 2 Bedroom Extension to the rear
The provision of alternate entrance and access arrangements from Crag Avenue to serve the permitted data storage centre, energy centre and substation development permitted under Reg. Ref. SD18A/0068, as amended by Reg. Ref. SD19A/0185 including the provision of ducted services connections between the permitted substation on site (permitted under Reg. Ref. SD18A/0068 as amended by Reg. Ref. SD19A/0185) and existing services to the south of the Grand Canal. The proposed ducted services connections will exit the permitted substation compound and run southward, crossing beneath the Grand Canal by way of a horizontal directional drill, before proceeding east and west to connect to existing services located to the south of the Grand Canal. This proposed development is also located on lands within the Grand Canal Corridor to the north of the R134 Regional Road, Clondalkin, Dublin 22.
Conversion of the attic to storage including a new dormer structure with 2 windows to the rear elevation and a new velux rooflight to the front elevation, all at roof level.
Full Planning Permission for fully serviced extensions to existing warehouse units including all associated and auxiliary site works and connection to existing mains services at 2 Park West Road, Park West Industrial Estate, Co. Dublin, D12 T201, and 8 Heaney Avenue, Park West Industrial Estate, Co. Dublin, D12 TW90.
Planning permission for the proposed development will consist of modifications to the permitted residential development of 86 no. residential units over retail/restaurant uses (reg. ref. 3798/18, 3941/20, 2517/21) within blocks 70 and 72 as follows: modifications to the private amenity spaces attached to 65 no. residential units at ground, first, second and third floor levels to provide winter gardens in lieu of previously permitted balconies including alterations to the existing curtain walling and permitted elevations. The floor area of the apartments and private amenity spaces remains unchanged from that previously permitted. Omission of previously permitted canopy at fourth floor level. The total number of apartment units (86 no.), designated car parking spaces (86 no.) bicycle parking spaces (167 no.) and gross floor area of blocks 70 and 72 all remain as previously permitted.
Permission for development on this site (1.26 ha). The proposed development will consist of modifications to the permitted residential development of 84 no. residential units over retail/ restaurant uses (Reg. Ref. 3798/18) with Blocks 70 and 72 and involves the provision of 1 no. additional 1 bed apartment unit at second floor level and 1 no. additional 1 bed unit at third floor level in lieu of part of the previously permitted community rooms. The gross floor area of each of the permitted community rooms will be reduced from 164 sqm to 49 sqm at both second and third floor levels. Permission is also sought for modifications to the shared basement accommodation involving insertion of 2 no. additional car parking spaces and all associated site and development works. The total number of apartment units within Block 70 and 72 will increase from 84 no. to 86 no. units and designated residential car parking spaces will increase from 84 no. to 86 no. spaces.
Permission for development on this site (1.26ha). The proposed development will consist of modifications to the permitted residential development of 84no. residential units over retail/restaurant uses (Reg. Ref. 3798/18) within Blocks 70 and 72 as follows: - Replacement of existing basement level plants rooms with new entrance lobbies accommodating lift/staircore and plant areas and extending to the permitted ground floor foyer areas within both Blocks 70 and 72. New entrance doors are to be inserted into the proposed basement lobby area on the northern elevation of Block 70 and the south western elevation of Block 72. The gross floor area of the permitted Block 70 increases from 5,715sq.m to 5,855sq.m. The gross floor area of the permitted Block 72 increases from 4,985sq.m to 5,126sq.m. Amendments to the penthouse levels (fifth floor level) elevations of both Blocks 70 and 72 involving the provision of aluminium cladding, windows and doors in lieu of previously permitted glazed curtain walling and revised materials on the penthouse canopies. Internal reconfiguration of the permitted apartments, hallways lift/stair cores and lobby areas to provide for storage areas in lieu of previously permitted ensuite bathrooms within all apartments, fire vents and additional circulation spaces to hallways within both Blocks 70 and 72. Replacement of the permitted green roofs on both Blocks 70 and 72 with a standard roof finish. Permission is also sought for modifications to the shared basement accommodation involving reconfiguration of the permitted car parking spaces and all associated site and development works. The total number of apartment units (84no.), designated car parking spaces (84no.) and bicycle parking spaces (167no.) all remain as previously permitted.
Change of use of existing 20 sq./m garage to habitable space and construction of a 27.7 sq./m single storey extension to the rear of existing dwelling.
Construction of a 242 bedroom hotel in a building ranging in height from 7 to 10 storeys over ground and lower ground floor levels; the development will include the lower ground floor accommodating 202 car parking spaces; 54 bicycle parking spaces, plant, stores and ESB substation; ground floor accommodating hotel entrance and reception area; restaurant and bar; outdoor terrace and patio with canopies; function room; meeting rooms; kitchen, staff facilities; stores, toilets and plant; ground floor mezzanine accommodating meeting rooms; admin office; store and laundry facilities; 1st to 9th floor accommodating 242 hotel bedrooms including 17 suites; 10th floor accommodating gym/yoga studio; plant, storage and a roof terrace; vehicular access from both the N7 slip road and Knockmeenagh lane with link street across the site; upgrade works to Knockmeenagh lane; landscaping; boundary treatment; wastewater pumping station; associated signage and all site development works and services; the site is located between Knockmeenagh Lane to the north, St. Brigids cottages to the east, the Nass Road (N7) to the south and the Nass Road Business Park to the west.
The development proposed will supersede the permitted ICT Facility 4 under Reg. Ref.: SD20A/0309, as previously amended under Reg. Ref.: SD22A/0093 and Reg. Ref.: SD23A/0158. A five-year planning permission is sought in respect of this proposed development. The proposed development comprises the following: • Construction of an ICT Facility Building (ICT Facility 4), with a Gross Floor Area (GFA) of 15,744 sq.m and a parapet height of c. 21.80m (with flues located at roof level, c. 4.5m over parapet height), over 3 no. levels, located in the southern portion of the wider landholding. This ICT Facility includes an associated external plant area of c. 1,796 sq.m over two levels, accommodating 22 no. emergency generators and associated flues. • The ICT Facility building will accommodate ICT equipment halls, associated electrical and mechanical plant rooms, loading bays, maintenance and storage space, office administration areas and screened plant. • Construction of ancillary structures including a guard hut, fire hydrant water storage tanks, fire hydrant pump plantroom, water mist fire protection pump plantroom and water tanks, and cold water plantroom to the west of the proposed ICT Facility 4. • Construction of a revised internal road network and circulation areas to serve ICT Facility 4, footpaths, provision of 25 no. car parking spaces (including 2 no. disabled parking bays) and 18 no. cycle parking spaces within a bike shelter. • Lighting, boundary treatments and all ancillary and associated development (including the construction of an underground foul and storm water drainage network, and utility cables). • Hard and soft landscaping and planting, lighting, screening, and all associated works, including underground foul and storm water drainage network, boundary treatments and security fencing, attenuation areas, and utility cables. An EPA-Industrial Emissions Directive (IE) licence will be required to facilitate the operation of the proposed development.
Single storey extension at second floor level to the east (front) and south (side) elevations of the existing nursing home (under construction) consisting of additional staff facilities.
Retention of 2 6.0m high and 1 7.0m high flagpole at the south east corner of the site adjacent to the intersection of Monastery Road & Monastery Park.
Amendments to the development permitted under Reg. Ref. SD20A/0309 comprising: alterations to permitted ICT Facility buildings 2 and 3, to include internal reconfiguration of the ICT equipment halls, associated electrical and mechanical plant rooms, loading bays, maintenance and storage space, office administration areas, and reconfiguration of screened plant; alterations to the external facades of permitted ICT Facility buildings 2 and 3 to include modification and reconfiguration of fenestration, louvers, loading bays, and access doors, along with an increase in height of 1.2 metres to main parapet level and reduction in the height of rooftop plant to not exceed the parapet height of the buildings, along with the omission of previously permitted flues and exhaust ducts at roof level; omission of emergency generators and associated flues from permitted ICT Facility buildings 2 and 3; The proposed amendments to ICT Facility buildings 2 and 3 result in an increase in their gross floor area (GFA) of 2,511sq.m for each building, resulting in an overall increase in the GFA of the two buildings of 5,022sq.m; Alterations to the water storage tanks serving the permitted ICT Facility buildings, including total increase of 268 sq.m GFA to the permitted pumprooms and a reduction in the scale of the associated water storage tanks. All associated and ancillary works; The application site is subject to an EPA Industrial Emissions Licence relating to the Energy Centre permitted on site (under Reg. Ref.: SD18A/0068 as amended by Reg. Ref.: SD19A/0185).
Provision of 4 new information and communications technology (ICT) Facility buildings and associated development at the subject site, superseding elements of the extant planning permissions on site (Reg. Ref.: SD18A/0068 and Reg, Ref.: SD19A/0185). The application site is subject to an EPA Industrial Emissions Licence (Ref. No,: P1113-01) relating to the Energy Centre permitted on site, The single storey Energy Centre, gas pressure reduction station, and 110kV Gas Insulated Switchgear (GIS) substation permitted under Reg, Ref.: SD18AI0068 and Reg. Ref.: SD19AI0185 will be constructed as previously approved and are not affected by the current application. The proposed development will comprise the following: The construction of 4 ICT Facility buildings (ICT Facilities 1, 2, 3, and 4) with a combined total gross floor area {GFA) of c. 47,564.5 sq.m, Each ICT Facility building includes associated external plant areas, totalling c, 20,649.5 sq,m, ICT Facilities 1, 2, and 3 will be located in the eastern portion of the site, and each comprise a GFA of c. 15,196 sq.m (including ancillary office and administration space) over part two and part three levels with a maximum height of c, 25 metres and a parapet height of c, 19.5 metres, Each of the ICT Facilities will include an associated external plant area of c, 6,624 sq,m, ICT Facility 4 will be located in the southern portion of the site and comprises a GFA of c, 1,976.5 sq,m (including ancillary office and administration space) over two levels with a maximum height of c, 15 metres and a parapet height of c. 10.5 metres, This ICT Facility includes an associated external plant area of c. 777.5sq.m, Each ICT Facility building will accommodate ICT equipment halls, associated electrical and mechanical plant rooms, loading bays, maintenance and storage space, office administration areas, and screened plant. Construction of internal road network and circulation areas, footpaths, provision of 153 no. car parking spaces and 54 no, cycle parking spaces. Connections to vehicular access routes, roads, services and permitted infrastructure relating to the Energy Centre and 110kV GIS substation permitted under Reg, Ref.: SD18A/0068 and Reg, Ref.: SD19A/0185. Provision of emergency generators with associated flues, water storage tanks and associated pump rooms (comprising 150 sq,m in total) to serve each of the proposed ICT Facility Buildings. Hard and soft landscaping and planting, lighting, and all associated works, including underground foul and storm water drainage network, boundary treatments and security fencing, attenuation areas, and utility cables.
Alterations to the development permitted under Reg. Ref.: SD18A/0068, as previously amended under Reg. Ref.: SD19A/0185 and Reg. Ref.: SD20A/0242, and to the development permitted under Reg. Ref.: SD20A/0309, as previously amended under Reg. Ref.: SD22A/0093. The proposed alterations in summary comprise the provision of an altered energy centre design and all associated development, along with minor alterations to the permitted site layout, provision of a gas AGI, and all ancillary works. The development, for which a 5-year planning permission is sought, will comprise the following: Construction of a revised energy centre in the western part of the subject site, to accommodate alternate generation technology, including 10 no. gas generation turbines (all with associated flues, 8 no. c. 33 metres (m) in height and 2 no. c. 15 m in height), 2 no. steam turbines including 2 no. steam turbine generator enclosure buildings with a gross floor area (GFA) of 219 sq.m each and a height of c. 6.2 m, associated steam turbine generator distribution and control structure with a GFA of 84 sq.m and an overall height of c. 4.2 m, and 2 no. steam turbine / air cooled condenser structures with a height of c. 25.4 m. Construction of 8 no. 33/20kV transformer bays to the southeast of the energy centre, with a further 12 no. gas / steam transformers to serve the proposed turbines to the west of the energy centre. Provision of 3 no. 13.6 m high fuel storage tanks, a fuel oil enclosure building (with a GFA of 50 sq.m and an overall height of c. 3.8m), a fire pump enclosure building (with a GFA of 65 sq.m and an overall height of c. 3.2 m) along with 3 no. c. 14.1 m high sprinkler tanks, a c. 14.5 m high water tank, and a water treatment plant building (with a GFA of 218 sq.m and a maximum height of c. 17 m including rooftop plant). Provision of 6 no. black-start / emergency generators to the south of the energy centre with an overall height of c. 5 m; Provision of a single storey over basement level powertrunk building (with a GFA of 932 sq.m and an overall height of c. 4.1 m) to the southeast of the proposed energy centre. Provision of a 3-storey over basement medium voltage / low voltage building (with a GFA of 3,161 sq.m and an overall height of c. 16.3 m) to the southwest of the proposed energy centre. Provision of 2 no. transformers adjacent to the substation constructed under Reg. Ref.: SD18A/0068, as amended by Reg. Ref.: SD19A/0185 (located to the southwest of the proposed energy centre). Provision of a guard hut with a GFA of 21 sq.m and with a height of c. 3.2m, to the west of the medium voltage / low voltage building. Provision of a Gas AGI (above-ground installation) to the southwest of the subject site within a fenced compound, accommodating a single storey control room building with a GFA of 10 sq.m and overall height of c. 3 m, a plant kiosk with a GFA of 17 sq.m and an overall height of c. 3 m, and a boiler house with a GFA of 13 sq.m and an overall height of c. 3m. Reorientation of permitted ICT Facility Building No. 4 to accommodate the revised energy centre layout (with no other change to this permitted building). Associated and ancillary alterations to the site layout relating to landscaping, parking (including 18 no. car parking spaces, and bicycle parking within a covered bicycle shelter to serve the energy centre) and roads layouts, lighting and services, boundary treatments, drainage, landscaping, and all associated and ancillary works. An Environmental Impact Assessment Report (EIAR) will be submitted to the Planning Authority with the planning application and the EIAR will be available for inspection or purchase at a fee not exceeding the reasonable cost of making a copy at the offices of the Planning Authority. An EPA-Industrial Emissions Directive (IE) licence will be applied for to facilitate the operation of the proposed development.