Permission for conversion of existing attic space to two bedrooms and WC. Works to include erection of a dormer flat roof to rear of existing house with zinc cladding or similar and two windows.
Alterations to planning Reg. SD20B/0073 consisting of construction of a first floor extension to the side of existing dwelling and attic conversion to include 2 dormer windows to rear of dwelling.
Construction of a 3.5sq.m single storey extension to front; 14.8sq.m single storey extension to rear of existing dwelling; change of use of 11.7sq.m garage to study.
The proposed development includes retention permission for the reorientation of the gas AGI (above-ground installation) compound permitted under SDCC Reg. Ref.: SD23A/0158 and to retain an existing Gas AGI skid located to the north of the gas AGI compound. The development also includes the retention and completion of an extension to the existing Gas AGI compound to the south, to provide for a pressure regulating and metering station (PRMS) compound area. The PRMS compound extension comprises the following buildings and gas related infrastructure:•Skid House structure with a total area of c. 118 sq.m and overall height of c.3m. •E&I Kiosk with a total area of c. 11 sq.m and overall height of c. 2.7m •Boiler House comprising 2 no. individual units (Boiler House 1 & Boiler House 2) both with an area of c. 22 sq.m and overall height of c.3m. •Gas Quality Building with a total area of c. 3 sq.m and overall height of c. 2.4.m • All associated and ancillary works including valves and pipework, site lighting, boundary treatments, landscaping, drainage and infrastructure. The proposed development is located within a site which is subject to an EPA Industrial Emissions (IE) Directive license.
Change of use from warehouse to self-storage use; • The demolition of the existing mezzanine floor (c. 53 sqm); • The construction of an additional floor measuring 797 sqm at 1st floor level, increasing the total gross floor area from 874.7 sqm to 1,618 sqm; • Associated site signage measuring at 9 sqm; • Minor internal and external alterations to facilitate the change of use from warehouse to self-storage use; • All associated site development works including cycle parking provision
Retention permission for the existing telecommunications compound, including enclosure and ground mounted equipment; Permission for the replacement of a 25m high lattice tower with a new monopole carrying antennae, dishes and associated equipment with ground works, including foundation (overall height of 20m, excluding lightning finial).
Removal of existing front boundary wall and replace with new selected stone boundary wall with new extended front vehicular access opening and widen existing front driveway.
The proposed development will consist of the internal alterations to the existing ground floor retail unit and external alterations to the Ninth Lock Road elevation through the reopening of existing blocked window openings, the formation of a new entrance doorway, and the installation of a new glazed shopfront, fascia and illuminated signage, and all associated site works.
Retention of detached shed/sensory room/study to rear garden
Amendments to the development permitted under Reg. Ref. SD20A/0309 comprising: alterations to permitted ICT Facility buildings 2 and 3, to include internal reconfiguration of the ICT equipment halls, associated electrical and mechanical plant rooms, loading bays, maintenance and storage space, office administration areas, and reconfiguration of screened plant; alterations to the external facades of permitted ICT Facility buildings 2 and 3 to include modification and reconfiguration of fenestration, louvers, loading bays, and access doors, along with an increase in height of 1.2 metres to main parapet level and reduction in the height of rooftop plant to not exceed the parapet height of the buildings, along with the omission of previously permitted flues and exhaust ducts at roof level; omission of emergency generators and associated flues from permitted ICT Facility buildings 2 and 3; The proposed amendments to ICT Facility buildings 2 and 3 result in an increase in their gross floor area (GFA) of 2,511sq.m for each building, resulting in an overall increase in the GFA of the two buildings of 5,022sq.m; Alterations to the water storage tanks serving the permitted ICT Facility buildings, including total increase of 268 sq.m GFA to the permitted pumprooms and a reduction in the scale of the associated water storage tanks. All associated and ancillary works; The application site is subject to an EPA Industrial Emissions Licence relating to the Energy Centre permitted on site (under Reg. Ref.: SD18A/0068 as amended by Reg. Ref.: SD19A/0185).
Provision of 4 new information and communications technology (ICT) Facility buildings and associated development at the subject site, superseding elements of the extant planning permissions on site (Reg. Ref.: SD18A/0068 and Reg, Ref.: SD19A/0185). The application site is subject to an EPA Industrial Emissions Licence (Ref. No,: P1113-01) relating to the Energy Centre permitted on site, The single storey Energy Centre, gas pressure reduction station, and 110kV Gas Insulated Switchgear (GIS) substation permitted under Reg, Ref.: SD18AI0068 and Reg. Ref.: SD19AI0185 will be constructed as previously approved and are not affected by the current application. The proposed development will comprise the following: The construction of 4 ICT Facility buildings (ICT Facilities 1, 2, 3, and 4) with a combined total gross floor area {GFA) of c. 47,564.5 sq.m, Each ICT Facility building includes associated external plant areas, totalling c, 20,649.5 sq,m, ICT Facilities 1, 2, and 3 will be located in the eastern portion of the site, and each comprise a GFA of c. 15,196 sq.m (including ancillary office and administration space) over part two and part three levels with a maximum height of c, 25 metres and a parapet height of c, 19.5 metres, Each of the ICT Facilities will include an associated external plant area of c, 6,624 sq,m, ICT Facility 4 will be located in the southern portion of the site and comprises a GFA of c, 1,976.5 sq,m (including ancillary office and administration space) over two levels with a maximum height of c, 15 metres and a parapet height of c. 10.5 metres, This ICT Facility includes an associated external plant area of c. 777.5sq.m, Each ICT Facility building will accommodate ICT equipment halls, associated electrical and mechanical plant rooms, loading bays, maintenance and storage space, office administration areas, and screened plant. Construction of internal road network and circulation areas, footpaths, provision of 153 no. car parking spaces and 54 no, cycle parking spaces. Connections to vehicular access routes, roads, services and permitted infrastructure relating to the Energy Centre and 110kV GIS substation permitted under Reg, Ref.: SD18A/0068 and Reg, Ref.: SD19A/0185. Provision of emergency generators with associated flues, water storage tanks and associated pump rooms (comprising 150 sq,m in total) to serve each of the proposed ICT Facility Buildings. Hard and soft landscaping and planting, lighting, and all associated works, including underground foul and storm water drainage network, boundary treatments and security fencing, attenuation areas, and utility cables.
Alterations to the development permitted under Reg. Ref.: SD18A/0068, as previously amended under Reg. Ref.: SD19A/0185 and Reg. Ref.: SD20A/0242, and to the development permitted under Reg. Ref.: SD20A/0309, as previously amended under Reg. Ref.: SD22A/0093. The proposed alterations in summary comprise the provision of an altered energy centre design and all associated development, along with minor alterations to the permitted site layout, provision of a gas AGI, and all ancillary works. The development, for which a 5-year planning permission is sought, will comprise the following: Construction of a revised energy centre in the western part of the subject site, to accommodate alternate generation technology, including 10 no. gas generation turbines (all with associated flues, 8 no. c. 33 metres (m) in height and 2 no. c. 15 m in height), 2 no. steam turbines including 2 no. steam turbine generator enclosure buildings with a gross floor area (GFA) of 219 sq.m each and a height of c. 6.2 m, associated steam turbine generator distribution and control structure with a GFA of 84 sq.m and an overall height of c. 4.2 m, and 2 no. steam turbine / air cooled condenser structures with a height of c. 25.4 m. Construction of 8 no. 33/20kV transformer bays to the southeast of the energy centre, with a further 12 no. gas / steam transformers to serve the proposed turbines to the west of the energy centre. Provision of 3 no. 13.6 m high fuel storage tanks, a fuel oil enclosure building (with a GFA of 50 sq.m and an overall height of c. 3.8m), a fire pump enclosure building (with a GFA of 65 sq.m and an overall height of c. 3.2 m) along with 3 no. c. 14.1 m high sprinkler tanks, a c. 14.5 m high water tank, and a water treatment plant building (with a GFA of 218 sq.m and a maximum height of c. 17 m including rooftop plant). Provision of 6 no. black-start / emergency generators to the south of the energy centre with an overall height of c. 5 m; Provision of a single storey over basement level powertrunk building (with a GFA of 932 sq.m and an overall height of c. 4.1 m) to the southeast of the proposed energy centre. Provision of a 3-storey over basement medium voltage / low voltage building (with a GFA of 3,161 sq.m and an overall height of c. 16.3 m) to the southwest of the proposed energy centre. Provision of 2 no. transformers adjacent to the substation constructed under Reg. Ref.: SD18A/0068, as amended by Reg. Ref.: SD19A/0185 (located to the southwest of the proposed energy centre). Provision of a guard hut with a GFA of 21 sq.m and with a height of c. 3.2m, to the west of the medium voltage / low voltage building. Provision of a Gas AGI (above-ground installation) to the southwest of the subject site within a fenced compound, accommodating a single storey control room building with a GFA of 10 sq.m and overall height of c. 3 m, a plant kiosk with a GFA of 17 sq.m and an overall height of c. 3 m, and a boiler house with a GFA of 13 sq.m and an overall height of c. 3m. Reorientation of permitted ICT Facility Building No. 4 to accommodate the revised energy centre layout (with no other change to this permitted building). Associated and ancillary alterations to the site layout relating to landscaping, parking (including 18 no. car parking spaces, and bicycle parking within a covered bicycle shelter to serve the energy centre) and roads layouts, lighting and services, boundary treatments, drainage, landscaping, and all associated and ancillary works. An Environmental Impact Assessment Report (EIAR) will be submitted to the Planning Authority with the planning application and the EIAR will be available for inspection or purchase at a fee not exceeding the reasonable cost of making a copy at the offices of the Planning Authority. An EPA-Industrial Emissions Directive (IE) licence will be applied for to facilitate the operation of the proposed development.
Removal of two existing prefabricated classrooms and construction of a four classroom, two storey extension to the west of the existing school buildings, together with connections to services and all associated site works.
27sq.m first floor extension over an existing ground floor to the front, rear and gable.
370sqm side and rear extension, new entrance, and new facade to front elevation.
Planning permission sought for to remove the existing garage to the side of the existing dwelling & replace with a new extended ground floor extension with a new first floor extension over with tiled roofs over to match existing to the side of the existing dwelling; internal alterations to include new attic conversion and associate site works.
Modifications to the Primary Healthcare Centre as permitted under Reg. SD11A/0135 (An Bord Pleanala Ref. PL06S.239890) and SD20A/0054 comprising of relocation of existing bus shelter on Boot Road (Bus Stop No. 3465) by c.75m northwards and construction of a new stainless steel and glass bus shelter including a double-sized internally illuminated advertising panel; Construction of an external stair core from the basement car park to surface level with associated changes to car parking layout.
Alterations to previously approved, but not yet constructed development under planning Ref. Ref. (SD11A/0135 - Block A was approved as a primary health care building and will remain so; Block B was approved as a nursing home building and permission is now sought to use that building as a primary health care us; Permission is also sought for an external café and relocation of sub-station from entrance area to a position on Fonthill Road); alterations to Block A of 3,249sq.m consist of minor internal reconfiguration to stair No. 1 cores, position of lift shafts and circulation areas; alterations to Block B of 3,521sq.m (previously approved use as a nursing home) to facilitate the use as a primary healthcare centre include internal reconfiguration to provide 10 consultation rooms; 37 offices; 7 clinic rooms; 4 administration/reception; 4 large group rooms and associated ancillary uses including a new external lift and stair to car park; a total of 149 car parking spaces are to be provided for the proposed development; this includes 125 spaces at basement level including 6 accessible car parking spaces and 24 spaces at surface level including 3 accessible car parking spaces; alterations to the previously approved permission also include for 20 new bicycle parking spaces; new plant space and storage; the previously approved entrance from Boot Road/Convent Road providing pedestrian, cycle and vehicular access including previously approved landscaping, remain as approved.
Demolish an existing single storey glazed conservatory to the rear. Erection of a new single storey flat roof extension to the rear. Erection of a new single storey porch structure and flat roof canopy to the front. Widening of existing vehicular entrance and all associated alterations & site works to the existing two storey house.
Clonmill Limited are applying for Permission, for the proposed amalgamation of shop units 19 and 20, at The Mill Shopping Centre Clondalkin, Ninth Lock Road, Clondalkin, Dublin 22. The proposed development will consist of the amalgamation of the existing retail Unit 19 (c. 78 sq.m) and existing retail Unit 20 (c. 74 sq.m) into a single retail unit 19/20 c. 155 sq.m through the removal of the existing wall between the two units. The existing entrance to Unit 20 is to be closed with a partition wall and the shop front glazing to be removed and replaced with a glazing unit to match height to Unit 19. Including all associated site services and development works.
Change of use and amalgamation of Unit 24A with Dunnes Stores Cafe (units 25/26) to increase the cafe's size from 257sqm to 368sqm, including an extended mall seating area and all other associated site works/services
(1) The demolition of the existing shed/garage building to the rear of the existing dwelling; (2) the construction of 1 2-bedroom, 3 person detached single storey pitched roof mews dwelling with attic conversion, and a single storey flat roof rear projection located to the rear of the existing dwelling and fronting Brideswell Lane; (3) the vehicular entrance is off Brideswell Lane; (4) connection to all public services; (5) all necessary ancillary site development works to facilitate this development.
1 industrial storage building to the west of the main complex with an area of 465.3sq.m and a height of 8.8m; all associated site works and utility connections.
Conversion of an existing single storey structure into a two bed mews dwelling with one reception room; kitchen/dining area; bathroom; rear garden with all associated site works; existing structure will be given a new pitched roof; parking will utilise the existing three spaces off Brideswell Lane.
Modifications to the ground floor layout and shop facade and will include for: (a) Single-storey extension to front of the existing store to provide a DRS facility to allow customers to return plastic beverage bottles to a reverse vending machine in store; (b) The removal of the existing entrance/exit pod; (c) The removal of the existing trolley bay; (d) Proposed free-standing trolley bay; (e) Proposed alteration works to store elevation; (f) Alteration works to car park area; (g) All ancillary works required to complete to the required Building Regulations standards.
The proposed development will consist of: Changes to existing hotel signage with the erection of 6no. signs and all other associated site development works. Sign No.1 (4.5m x 1.5m) is a high level sign to replace the existing sign on the northern elevation. Sign No.2 (4.1m x 1.4m) is a high level sign to replace existing on the southern elevation. Sign No.3 (4.5m x 1.5m) is a high level sign to replace existing on the western elevation. Sign No.4 (3.9m x 0.3m) is a low level sign above the main entrance of hotel to replace existing. Sign No.5 comprises 2no. new circular panel signs (600mm x 600mm each), either side of the main hotel entrance. All signs are to be internally illuminated by means of LEDs, giving face illumination only.
The proposed development will consist of: Changes to existing hotel signage with the erection of 6no. signs and all other associated site development works. Sign No.1 (6.1m x 2.1m) is a high level sign to replace the existing sign on the northern elevation. Sign No.2 (4.6m x 2.1m) is a high level sign to replace existing on the southern elevation. Sign No.3 (5.3m x 2.2m) is a high level sign to replace existing on the western elevation. Sign No.4 (3.9m x 0.3m) is a low level sign above the main entrance of hotel to replace existing. Sign No.5 comprises 2no. new circular panel signs (600mm x 600mm each), either side of the main hotel entrance. All signs are to be internally illuminated by means of LEDs, giving face illumination only.
Retention of internal layout changes which include removal of internal walls to extend class 2; modification to toilet to classroom 2 to extend toilet area; addition of corridor with addition of office and storage to class 1; external change of south elevation change from window to external door to access class 3 all with ancillary works.
Planning Permission for (1) The demolition of the existing garage building to the rear of the existing dwelling (2) The construction of 1no. 2 bedroom 3 person detached single storey pitched roof mews dwelling with a single storey flat roof rear projection located to the rear of the existing dwelling and fronting onto Brideswell Lane (3) The vehicular entrance is off Brideswell Lane (4) Connection to all public services and all necessary ancillary site development works to facilitate this development at the rear of 101 Boot Road, Clondalkin, Dublin 22, D22 V3Y6.04
Demolition of existing single storey side extension and permission to sub-divide existing house to construct a two storey, semi-detached (end of terrace) house to side; connection to public foul sewer, shared parking space to front and all associated site works.
The development shall consist of permission to relocate existing front door and all associated site works.
Alterations to existing boundary wall/railings; proposals to construct a new pedestrian entrance gate and new concrete path to existing bank with all associated site works.
(1) The demolition of the existing shed/garage building to the rear of the existing dwelling; (2) the construction of 2 2-bedroom, 3 person detached two storey pitched roof mews dwellings with a single storey flat roof rear projection, located to the rear of the existing dwelling and fronting onto Brideswell Lane (3) the vehicular entrance is off Brideswell Lane (4) connection to all public services, and (5) all necessary ancillary site development works to facilitate this development.
Amendments to previous approved Planning Permission Ref. SD23A/0152, for the Demolition of existing Shed and Garage buildings to the rear of existing dwelling and construction of 1 no. 2-bedroom, pitched roof, detached mews dwelling house fronting on to Brideswell Lane, including vehicular entrance off Brideswell Lane, connections to public services and all associated site works. The proposal includes provision of rear garden private open space and 2 parking spaces accessed off Brideswell Lane. Amendments for which this Planning Application refers are for the change of house type from a 2 bedroom to a 4 bedroom pitched roof, detached mews dwelling house fronting on to Brideswell Lane. Note: the Demolition of existing Shed and Garage buildings to the rear of existing dwelling and the provision of 2 parking spaces accessed off Brideswell Lane is as per previous Planning Ref: SD23A/0152
1. Demolition of existing Shed and Garage buildings to the rear of existing dwelling. 2. Construction of 1 no. 2-bedroom, pitched roof, detached mews dwelling house fronting on to Brideswell Lane, including vehicular entrance off Brideswell Lane, connections to public services and all associated site works. The proposal includes provision of rear garden private open space and 2 parking spaces accessed off Brideswell Lane.
Social housing development consisting of 10 one bed units in a two to three storey apartment building, associated car parking and bicycle parking, bin store, water pump house, new vehicular access onto Old Nangor Road, new pedestrian access onto Old Nangor Road, landscaping, boundary treatments, public lighting and all associated site and engineering works necessary.
Parking area to the front with dropped kerb for access; new folding wrought iron gates in keeping with the existing.
A social housing development comprising of 10 one bed units in a three storey apartment building, associated car parking and bicycle parking, bin store, new vehicular access onto Old Nangor Road, new pedestrian access to replace existing vehicular entrance, landscaping, boundary treatments and all associated site and engineering works necessary to facilitate the development.
Residential development consisting of the construction of a four to six storey building accommodating 44 apartments comprised of 22 one bedroom apartments and 22 two bedroom apartments; vehicular access to the proposed development will be via St. John's Road with 10 car parking spaces and 24 bicycle parking spaces and ancillary services all on a site of 0.31 hectares to the rear of St. John's Road with frontage onto Fonthill Road.
Permission for residential development comprising 9 dwellings. The proposed development is comprised of: (1) 2 Type A, 2 bed two storey semi-detached houses; (2) 1 Type B, 3 bed two storey detached house with attic conversion; (3) 2 Type C, 3 bed two storey end terrace houses with attic conversions; (4) 2 Type D, 2 bed two storey mid terrace houses with attic conversions; (5) 2 Type E, 3 bed two storey end terrace houses with attic conversions; (6) proposed new vehicular access road from St. Johns Road (located on lands owned by South Dublin County Council); (7) connections to all services and all ancillary site development works and (8) a pedestrian access gate at the intersection of Commons Road and Fonthill Road (located on lands owned by South Dublin County Council).
Retention permission for two shed structures located in the rear garden and all associated site works.
The development will consist of the material alteration to existing medical centre (150msq) with the proposed expansion of the medical centre to provide additional floor Area (25msq) provided by the proposed reduction of the adjacent existing retail shop area reduced from 96msq to 71msq, new window to the east elevation in accordance with lodged plans and documents to include all associated/ancillary works
Construction of a new detached single storey pitched roof shed building within the rear garden off the existing house. Part of the new shed building will be used as a home office. Connections to all services and all necessary ancillary site development works to facilitate this development.
Change of use of the existing building on site (comprising 763sq.m gross floor area) from office use to light industrial use (comprising the assembly of hampers and online orders at first floor area, digital device repair and refurbishment at second floor level with ancillary staff canteen and reception area at ground floor level); The development also includes the provision of a bicycle store (6 spaces) at ground I undercroft level, along with all ancillary works.
(1) Demolition of the existing garage attached to the side of the existing dwelling (2) Construction of a two storey pitched roof side extension, and with the two storey extension projecting beyond the rear of the existing dwelling (3) Single storey flat roof rear extension for the width of the existing dwelling (4) Internal alterations at ground and first floor level within the existing dwelling to facilitate the new extension (5) increased width vehicular entrance of the public road to provide additional off road parking and (6) all necessary ancillary site development works to facilitate this development
Planning Permission for (1) The construction of 1no. 3 bedroom 5 person detached two storey pitched roof dwelling (no 18A St Johns Road) located within side garden of existing dwelling (no 18) and fronting onto St Johns Road (2) New vehicular entrance of the public road to provide off road parking and (3) Connection to all public services and all necessary ancillary site development works to facilitate this development. Note: Demolition of the existing garage attached to the side of the existing dwelling is as per previous Planning Ref: SD23B/0447 at18.
The construction of a new single storey extension to the rear of existing truck and van test centre which will include the erection of a raised parapet and external cladding and external signage to the elevations and for all ancillary site works at Murphy's Truck Centre, Turnpike Road, Ballymount, Dublin 22.
2 industrial storage buildings to the west of the main complex; Building no. 1 - 460sq.m with a height of 8.8m; Building no. 2 - 244.4sq.m with a height of 7.0m; all associated site works and utility connections.
The development will consist of the change of use of the ground, first and second floors from class 3 office use to class 8 for use as a health centre / clinic along with all associated works.
Demolition of the existing side extension 34sq.m; New side/rear extension to be built (rear extension to be two-storey), total new extension 72sq.m.