For the change of restricted sale and use to unrestricted use and sale of the dwellings by all classes of persons (removal of condition no 2 of planning file 08/1496 and An Bord Pleanala Ref: PL 27.231988) for development of 4 houses
2 storey one bedroom detached house
Widening an existing pedestrian entrance in the front garden wall to create a vehicular entrance and change part of the front garden to a parking area for 2no vehicles
Proposed relocation and upgrading of existing vehicular entrance realignment of part of access road (circa 85 metres) & ancillary works
Proposed dwelling, waste water treatment system to EPA standards, garage, driveway and associated works
The reclamation of land through the filling of material comprising clay, silt, sand, gravel or stone on a site having an area of 4.41 hectares, for the purpose of improvement of land, together with site access and roadway and other ancillary site works. The proposed development relates to an activity, which requires a waste licence
Dwelling, wastewater treatment system to EPA standards, garage, entrance and associated works
Existing extension to side & rear of existing dwelling and Permission for new single storey rear extension, alterations to fenestration, addition of rooflight to front elevation & upgrade of waste water treatment system
1. Demolition of existing ind building units totalling (C.2784.4m2) comprising of a c.7.1m high Overall Main Building (c.2460m2), a c.4.2m high Sub-station (c. 107.3m2), a c.3.6m high Guardhouse (c.106.2m2), a c.3.6m high East-Building (c.39.1m2), c.5m high Water Tank (c.56.8m2) &c.2.6m high Pump House Building (c.15.1m2), assoc works. 2. Dev of 3 no. Data Centre Buildings, ancillary offices & plant comprising of: Data Centre Building A, - a single storey Data Centre Building, with mezzanine 1st floor level offices (GFA c.10,564m2, building height c.13,658m & structures c.15,137m), made up of 2 no. Data Halls & loading areas with assoc 2 no. Dock Levellers & including 10 no. c.14m high flues, & adjacent 1 no. Standby Power Generation Compounds, consisting of 10 no. HV Diesel Generators &belly tanks (GFA c.530 m2), 1 no. storage fuel tank (GFA c.15m2). Data Centre Building B – a single storey data centre building with mezzanine 1st floor level offices (GFA c.18,508m2, building height c.13,658m &structures c.15,137m), made up of 4 no. Data Halls &loading areas with associated 2 no. Dock Levellers &including 20 no. c.14m high flues, &adjacent 2 no. Standby Power Generation Compounds, consisting of 20 no. HV diesel Generators &belly tanks (GFA c.1,060 m2), 2 no. storage fuel tanks (GFA c.30m2). Data Centre Building C – a single storey data centre building with mezzanine 1st floor level offices (GFA c.18,508m2, building height c.13,658m & structures c.15,137m), made up of 4 no. Data Halls & loading areas with associated 2 no. Dock Levellers &including 20 no. c.14m high flues, &adjacent 2 no. Standby Power Generation Compounds, consisting of 20 no. HV Diesel Generators & belly tanks (GFA c.1,060 m2), 2 no. storage fuel tanks (GFA c.30m2). 3. Upgrading of existing 110 kV Substation to comprise of Compound (c. 8539m2) consisting of 11 kV GIS Switch Room (GFA c.708m2), &4 no. External Transformers (GFA c.550m2), a grid connection, security fence & all assoc works & services. 4. Dev of 1 no. Fire Hydrant Pump Hse (GFA c.129m2) with Sprinkler Tank (c.49m2), 1 no. single storey Security Guard Hse (GFA c.48m2) &2 no. vehicular accesses, internal access rds & 224 no. surface car parking spaces. 5. An upgraded attenuation basin, a proposed ww treatment plant &polishing filter. 6. All assoc site services, with c.2.7m high palisade fence, landscaping, boundary & all assoc site development works above & below ground. An EIAR has been prepared in respect of the proposed dev
Removal of existing septic tank, installation of new septic tank, percolation area to current standards and associate works
1. conversion of garage attached to the existing house and changes to elevations; 2. retention of construction of two no. outhouses for use as stick shed, greenhouse, workshop and storage shed; 3. retention of storage extension to existing stables; 4. retention of change of position of entrance, house, driveway and site boundaries and all ancillary site works
Dwelling, waste water treatment system to EPA standards, garage, entrance and associated works
Dwelling, waste water treatment system to EPA standards, garage, driveway and associated works
Construction of a single storey detached dwelling (with internal mezzanine area), well, effluent treatment system to current EPA standards, and all ancillary site works
(a) Construction of a new four-bedroom dwelling, (b) installation of a new treatment unit and percolation area, (c) new vehicle entrance onto public road (L1152), (d) all associated site works
The proposed development occupies part of the site of (and will supersede) a previously permitted data centre development under Reg. Ref. 20/1285. The proposed development, for which a ten-year permission is sought, consists of the following: Demolition of the existing structures on site (industrial structures and outbuildings) and site clearance works; construction of 3 no. three storey information and communication technology (ICT) facility buildings, each with a gross floor area (GFA) of c. 16,206 sq.m (c. 48,618sq.m GFA in total), and with a parapet height of c. 19.5 metres; each of the 3 no. ICT buildings will accommodate ICT equipment rooms, mechanical equipment rooms, staff welfare facilities, ancillary office space, security rooms, storage, and loading bays; a customer compound, a power trunk building, a transformer compound and a water tank compound area are provided to the north of the ICT facility buildings; the development includes the extension of the existing road and serving the existing industrial park to access the subject site, with gated access points to the proposed ICT facility development to be provided off this roadway; construction of internal road network and circulation areas, footpaths, provision of 124 no. car parking spaces and motorcycle and cycle parking spaces; landscaping and planting, boundary treatments, lighting, security fencing, and all associated site works including underground foul and storm water drainage network, attenuation and percolation areas, and utility cable (including connections to the substation permitted under ABP Ref. 310090-21, resulting in the partial culverting of an existing drainage ditch), on an application site area measuring c. 9.69 hectares. An Environmental Impact Assessment Report (EIAR) has been prepared and will be submitted to the Planning Authority with the planning application
Change of use (removal of planning condition 2 of Planning Reference Number 08/642) from restricted use as a dwelling to use by all classes of persons, retention of revised height of dwelling and associated works
A new single storey extension to side of existing dwelling, minor modifications to internal layout of existing dwelling and associate works
The construction of a stable block and associate works
Demolition of a store room and reconstruction of a store room on the same footprint and associated works
The proposed development seeks permission to amend the development permitted under WCC Reg. Ref.: 23/72 and will consist of the following: • Reconfiguration of the internal layout of the 3-no. permitted ICT facility buildings to include ICT equipment rooms, mechanical rooms, switch rooms, electrical equipment rooms, office accommodation, storage and staff facilities at ground and first floor levels; • Amendments to the southern façade on all ICT facility buildings to include alterations to fenestration, extension of permitted louvered façade treatment, and associated alterations; • An increase of c.113 sq.m to the permitted external generator compound of each ICT facility building at ground floor to accommodate additional plant and equipment; • Amendments to plant and equipment layout at roof level and the provision of 1 no. additional roof-mounted emergency landlord generator on each ICT facility building; • Amendments to the permitted water services compound to provide for 1 no. sprinkler tank, 1 no. hydrant tank, 2 no. hydrant water tanks, 2 no. water storage tanks, 6 no. single storey pump rooms (with a gross floor area (GFA) of c. 52 sq.m each) and 1 no. single storey pump room of with a GFA of c. 46 sq.m; • Revisions to permitted site access arrangements including the omission of a permitted security hut and the provision of a revised sally port entrance system with a single storey gatehouse (c. 43 sq.m) and associated revised internal road network; • Relocation of permitted car parking spaces and the provision of 26 no. additional car parking spaces (149 no. spaces in total), Electric Vehicle (EV) car parking and ducting; • The proposed development also includes alterations to the permitted landscaping and planting, fuel filling areas, boundary treatments, security fencing, lighting, SuDS and drainage, and all associated and ancillary site development works. The operation of the development will require an EPA Industrial Emissions Directive (IE) Licence.
• construction of 2 No. 4 bedroom semi-detached dwellings, 2 no. 1 bedroom apartments & 2 no. 2 bedroom apartments with associated private open space and car parking. The development will include the extension of an existing access road forming part of Viewmount estate, and the provision of 292 sqm public open space & 25sqm of communal open space. • the site development and infrastructural works provide for water, foul and surface water drainage, and all associated connections; all landscaping and boundary treatment works including retaining walls; footpaths; and associated development works
Amendments and alterations to previously approved planning permission Pl. reg ref. 16/720 to include the following: 1. Revisions to finished floor levels in Estate 2, Viewmount, Knockadosan, Rathdrum, 2. Reconfiguration of road layout and revisions to road levels in Estate 2, Viewmount, Knockasosan, Rathdrum. 3. Revisions to configuration of individual site boundaries and house types to Estate 2, Viewmount, Knockadosan, Rathdrum to incorporate the addition of 3 no. dwelling units to increase the total number of units proposed from 106 to 109. 4. Proposed revisions to House Types to include the omission of 4 No. House Type 3A(3 bed semi detached) dwelling units, 1 No. House Type 4A2 (4 Bed detached) dwelling unit and 4 No. House Type 2A (2 bed terraced) dwelling units, and the provision of 7 No. House type 4A (4 bed semi-detached) dwelling units, 1 No. House Type 4A1 (double fronted 4 bed semi-detached) dwelling unit and 4 no. House Type 5A (3 bed terraced) dwelling units resulting in the above net 3 additional units. All of the above together with all associated site development works
Material change of use of part of farmyard and part of shed for operation of firewood cutting, bagging, storage and loading firewood for delivery off site and associated works
SECTION 42(1B) - in relation to PP 16/92 - 9 proposed detached dwellings. Extension to complete structures, which will be quick due to the ICF method of constructon. Complete drainage works & site works & landscaping
The development will consist of a new build extension to the hospital of 6,623m2, refurbishment and upgrade of the existing hospital of 2,561m2 and demolition of 2,077m2 (gross internal floor areas) on the site of St. Colman’s Hospital of 7.48 hectares. The new build extension will consist of two and three storey resident accommodation blocks staggered either side of a new central three storey circulation spine containing lifts, stairs and a new main entrance. The resident accommodation will provide 95 single bedrooms, each with ensuite, arranged within 3 x 25 Bed Households and 2 x 10 Bed Dementia Specific units. These Households and Dementia Specific units will include living, dining, kitchen, activities and ancillary facilities and access to courtyards and terraces. New plant-rooms including Sub-station and switch-room are also included. The existing A+B Blocks (commonly referred to as the H block due it’s shape) will be re-configured from multi-person bedrooms to accommodate Physiotherapy, Day Centre, Dementia Specific Day Centre, Family Overnight suite, administration functions, Staff welfare and Mortuary. The existing Catering, Dining Area and Chapel will also be upgraded and refurbished. The existing C+D block will be demolished and new surface car parking provided. This application includes associated landscaping, site services, Services Yard, generator, additional car parking and site circulation roads. It also includes for all site signage, utility connection works and ancillary site works associated with the project
Proposed dwelling, waste water treatment system to EPA standards, garage, entrance and associated works
Construction of a bungalow with attached shed, to widen and upgrade the existing agricultural entrance and upgrade of existing lane, provision of a new treatment system and percolation area to current EPA standards and all ancillary site works
In summary, the proposed development will consist of the: demolition of the existing one to two storey school buildings (c. 4,790 sq.m) and removal of temporary classroom accommodation (c. 372.1 sq.m); construction of a two to three storey school building (c. 10,937 sq.m) including classrooms, specialist teaching rooms, a Special Educational Needs (SEN) unit, a general purpose hall, multipurpose hall and administrative and ancillary spaces with solar photovoltaic panels at roof level; development of external play and social amenity areas, including the provision of 3 no. multi-use games areas / ball courts and an SEN garden; upgrade of the existing vehicular and pedestrian entrance off Poundbrook Lane; provision of a new set-down area for cars and school buses within the school grounds; implementation of traffic management measures to Poundbrook Lane relating to on-street parking; upgrade of existing car parking areas to provide a total of 89 no. new staff car parking spaces, including 1 no. electric vehicle parking space and ducting for future electric vehicle parking spaces, and 6 no. accessible parking spaces; provision of 200 no. bicycle parking spaces; provision of an internal emergency vehicular access route along the north-west boundary of the site; construction of an external storage shelter, covered work area and bin store; provision of landscaping, boundary treatments and site lighting; provision of associated drainage, attenuation and other site services, including the provision of an ESB substation and switch room; and, all related site development works. A full description of the proposed development is set out in the Planning Report prepared by RPS and submitted as part of the planning application package.
A 12.3 square metre plant room, a 30.0 square metre shed as built, also retention for change of use from attic to 33.7 square metre storage area in attic of house, retention of rooflights, and retention for minor elevation changes to door and windows to house and garage from previous planning permission (952472) and all associated siteworks
Full ten-year planning permission for development on this site located at Avoca River Park, Arklow, Co. Wicklow. The proposed development is to be located within the townlands of Shelton Abbey and Marsh. The site is bound to the west by the site of a permitted data storage facility development (permitted under Reg. Ref.: 201285), to the north by the access road to Avoca River Park, to the south by undeveloped lands and to the east by undeveloped lands beyond which is the M11 motorway. The proposed development consists of the following: •All site clearance and enabling works required to facilitate the development. •Construction of 2 no. energy centre buildings (Energy Centre 1 and Energy Centre 2) each with a height to parapet level of c. 13.85 metres. •Energy Centre 1 will comprise a gross floor area (GFA) of 5,965 sq.m. within a single storey building and will accommodate 12 no. generators. 4 no. flues 33 metres in height will be accommodated along with south-western elevation of the building. •Energy Centre 2 will comprise a GFA of 9,180 sq.m. within a single storey building and will accommodate 18 no. generators. 6 no. flues 33 metres in height will be accommodated along the south-western elevation of the building. •Construction of a battery compound to provide electricity storage and backup power, located to the northeast of Energy Centre 2, to comprise 27 no. battery arrays within a compound area of c. 0.7 hectares. A single storey MV switch-room building (c. 181 sq.m. GFA) will be provided to the west of the battery compound. •Provision of a transformer compound (to the northwest of Energy Centre 1), along with a welfare building (c.38 sq.m. GFA).•Provision of fuel storage tanks (2 no.) within a bunded compound to the north of Energy Centre 2.•Construction of a new access from the existing estate access road to the north of the site, internal road network and circulation areas, footpaths, provision of 6 no. car parking spaces and 4 no. cycle parking spaces. •Landscaping and planting, boundary treatments, lighting, security fencing and all associated ancillary and site works including underground foul and storm water drainage network (including on-site wastewater treatment system) and utility cables
Conversion of existing garage/store to a 'Granny Flat' and store and also the construction of a new sunroom to the rear of existing house
Revised entrance to create dual entrance and associated works
Proposed new vehicular entrance and associated works
Extend the appropriate period of 16/92 - nine detached 2-storey dwellings, a riverside walkway, landscaping and associated site development works
Installation of a concrete base to sit an Elliptical Milk Tank on and associated site
A new single storey extension to side of existing dwelling and associate works
Installation of a new agriculture shed and associated site works
Of an existing telecommunications support structure (previously granted under Plan Ref No 07/374) together with associated ground equipment cabinets within a fenced compound
Single storey dwelling with septic tank and percolation area together with all associated and ancillary site works
Proposed development. The proposed development includes an amendment to the development permitted under Reg. Ref. 21/1080, The proposed development will consist of the following to facilitate the above. Demolition of the existing structures on the western part of the site that comprises 4 no. industrial commercial buildings, an associated hut / outbuilding, a gas enclosure, and a tank with bund wall. The removal of the remains of a previously demolished building, areas of hard standing, and existing surface treatments. The relocation of the Energy Centre 1 to the western part of the site, which will supersede the previously permitted 110kV GIS substation compound at that location under ABP Ref: VA27.309252. The proposed development will provide for a revised energy centre design, to include the provision of 8 no. gas turbines (with associated flues of 25.15m in height), 4 no. black start emergency generators and associated transformers, 2 no. single storey fuel oil pump rooms with a gross floor area (GFA) of 90.17sq.m, a single storey air compressor building with a GFA of 88.9sq.m, 4 no. fuel tanks, 2 no. MCC control rooms with a GFA of 44.17sq.m, 3 no. fire water tanks, a single storey welfare, storage, and pump room building with a combined GFA of 160.97 sq.m, a two storey MV /LV building with a GFA of 655.54sq.m, 8 no. 11kV/ 33kV step-up transformers in the north of the site, water treatment equipment, and a security hut, all within a fenced compound. The proposed development includes landscaping and planting, boundary treatments, lighting, security fencing, car parking, and all site works including underground foul and storm water drainage network (including on-site wastewater treatment system), and utility cables, along with all associated and ancillary works. An EPA- Industrial Emissions Directive (IED) licence will be applied for to facilitate the operation of the proposed development
Construction of a 24 metre high free standing communications structure with its associated antennae, communication dishes, ground equipment, fencing and all associated site development works. the development will continue to form part of existing 3G and 4G Broadband network
Erect a two-bedroom dwelling (maisonette), over the Aughrim Butcher Shop. The 99.17 square meter maisonette has its main entrance through the rear gate and yard (private open space) beside and in line with the adjoining existing development entrances. Permission is also required for any ancillary site works including but not limited to, sewage, water, rear yard paving and car parking
Proposal to extend the existing first floor Office-Storage Area, over Aughrim Butcher Shop, out into the yard at the rear, at the same level, by 36.22 square metres. The extended area will include 3 number south facing Velux Roof Lights in the roof, toilets and any ancillary site works
Replacement of an existing 10m high support pole carrying associated antennae for an 18 metre high free standing communications structure with its associated antennae, communication dish, ground equipment, fencing and all associated site development works. The development will continue to form part of the existing 3G and 4G Broadband network
(i) the installation of a new 40,000lt above ground fuel storage tank with associated piping & dispenser cabinet, (ii) new above ground fill points, (iii) relocated air & water services unit Y (iv) associated drainage including a new 10,000 Class 1 separator
Single storey rear extension, and front porch to dwelling and associated works
A 10 year permission for the construction of an energy storage facility within a total site area of 0.48 hA to include containerised battery storage modules on concrete support structures, electrical transformer / inverter stations, associated electrical ducting / cabling, security fencing and CCTV security monitoring system, lightning protection poles and ancillary equipment
Two storey side extension to existing dwelling, together with retention permission for a partially built two storey rear extension together with permission for completion of roof to rear extension and all associated site works
Change of house type and site plan previously granted under Planning Ref 16/904 and also the provision of a double garage