Planning records
Showing 1-50 of 1,552 public recordsDwelling, rear extension and garage as built and permission for removal of existing septic tank, installation of new wastewater treatment unit and soil polishing filter, new site boundary and associate works
Proposed dwelling, waste water treatment system to EPA standards, garage, entrance drive and associated works
For a dwelling, garage, well, effluent treatment system, upgrading existing entrance & provision of a driveway & associated works. The site is accessed via existing right of way.
The construction of a single storey sunroom extension onto the side of house and for the construction of a front door porch with minor alterations to window and door configuration on rear elevation and side elevation including ancillary works. Retention permission is also sought for the upgrading of existing septic tank and percolation area to a new onsite wastewater treatment unit and percolation area in accordance with EPA standards at adjoining lands to north of site for which the applicant has easements to carry out such works
Extensions to dwelling including garage, toolroom, front entrance hall and orangery and associated works
Construct slatted cattle shed, concrete aprons and all associated site works
To demolish the existing 5m² porch & substandard 20m² outbuilding and erect a 90m² dormer extension to the rear along with minor alterations and revisions to the elevations and internal layout of the existing farmhouse and upgrade the existing on-site effluent disposal system to current EPA standards along with all site development works
15m2 replacement extension in lieu of the 15m2 sub-standard extension to the side with a 40m2 single storey extension to the rear along with minor alterations & revisions to the existing renovated 63m2 dwelling and a new on-site effluent disposal system to current EPA standards along with all associated site development works
(i) first floor extension to existing single storey weighbridge office (ii) above ground fire water storage tank to serve this building and development permitted under PPR 19/54 (iii) omission of office building permitted under PPR 19/54 and all associated site works
Single storey extension to building no. 1 (728 m2) and 2 no. battery storage kiosks and 2 no. invertors to northern façade of building no. 1, removal of ground mounted solar panels and construction of detached single storey building (120m2) to the south of building no. 1. single storey extension to building no. 2 of (152 m2) and all associated site development works
An amendment to Block 1 permitted under PPR 19/54 consisting of a single storey extension (281sqm) and all associated site works
Detached storage shed no. 1 (388.50m2), detached tool / battery shed no. 2 (38.9m2), 2 no. sprinkler tanks and pump house (13.95m2) located north of building no. 1. Retention sought for detached storage shed no. 3 (224.60m2) located north of building no. 2 and all associated works
As constructed weighbridge office extension, PRR 20/1282 and all associated site works
The installation of circa. 3,492sq.m array of solar photovoltaic (PV) panels on ground mounted frames on an agricultural plot within the existing Shelton Abbey Open Prison, together with ducting, underground electrical cabling, and all associated site works The proposed development is considered to be within the curtilage of a protected structure (RPS No. 40-05) listed under the current Wicklow County Development Plan 2022-2028. The proposed solar array installation will have no impact on the protected structure, located over 330.00 meters away from the proposed site.
The construction of a bungalow with new entrance and driveway off existing right of way, new effluent treatment system to current EPA standards and all ancillary site works
For proposed change of use from industrial/warehouse to plastics recycling facility and associated works
(A) The erection of an Independent Living Unit (granny flat), (B) Upgrading of existing sewerage treatment facilities to include a Bio-Crete Waste Water Treatment Plant with sand polishing filter to comply with EPA Code of Practice 2021 and (C) Ancillary site works
Alterations to a steel framed agricultural shed as a change to that permitted under 17/1393 and all associated site and ancillary works
Construction of a single storey detached training room structure, ancillary to the main Club House, with new course WC connected to the existing wastewater treatment facility on site and all associated landscaping works
Sunroom extension and additional first floor residential accommodation together with free standing storage outbuildings for uses ancillary to main house
For modifications to the dwelling and site granted permission under Reg Ref 20/746. For (1.) A reduction to the overall subject site area.(2) A revised location for the approved dwelling site layout/entrance driveway. (3). A revised location packaged effluent disposal system with mechanical aeration and polishing filter to current EPA standards (4.) A revised location for a proposed groundwater well and all together with required site and development works
Retention of extensions and front elevation to house as constructed
Outline Reg Ref 23/444. The development will consist of a dwelling circa 191msq, a domestic garage, packaged effluent disposal system with mechanical aeration and polishing filter to current EPA standards, a groundwater well, together with all required site and development works
The construction of a bungalow with garage, new vehicular entrance and driveway, new effluent treatment system to current EPA standards and all ancillary site works
Proposed new dwelling, upgrade to existing entrance, bored well, effluent disposal systems to EPA Cop 2009 standards and all associated site works
Erection of a ground floor extension (incorporating a domestic garage/store), first floor extension and to carry out alterations to existing dwelling house. Permission is also sought for a new replacement wastewater treatment system to current EPA standards and to decommission the existing system on site and to carry out associated ancillary site works
New dwelling house & driveway, a packaged effluent disposal system with mechanical aeration and polishing filter to current EPA standards & a groundwater well together with required site and development works
Construction of a 40 bedroom extension to existing hotel as granted under PRR 02/6916 & 03/8031, including associated alterations and additions to existing car park layout and associated works to existing effluent treatment system, together with revisions to site boundaries, all together with associated site works
1. Demolition of existing ind building units totalling (C.2784.4m2) comprising of a c.7.1m high Overall Main Building (c.2460m2), a c.4.2m high Sub-station (c. 107.3m2), a c.3.6m high Guardhouse (c.106.2m2), a c.3.6m high East-Building (c.39.1m2), c.5m high Water Tank (c.56.8m2) &c.2.6m high Pump House Building (c.15.1m2), assoc works. 2. Dev of 3 no. Data Centre Buildings, ancillary offices & plant comprising of: Data Centre Building A, - a single storey Data Centre Building, with mezzanine 1st floor level offices (GFA c.10,564m2, building height c.13,658m & structures c.15,137m), made up of 2 no. Data Halls & loading areas with assoc 2 no. Dock Levellers & including 10 no. c.14m high flues, & adjacent 1 no. Standby Power Generation Compounds, consisting of 10 no. HV Diesel Generators &belly tanks (GFA c.530 m2), 1 no. storage fuel tank (GFA c.15m2). Data Centre Building B – a single storey data centre building with mezzanine 1st floor level offices (GFA c.18,508m2, building height c.13,658m &structures c.15,137m), made up of 4 no. Data Halls &loading areas with associated 2 no. Dock Levellers &including 20 no. c.14m high flues, &adjacent 2 no. Standby Power Generation Compounds, consisting of 20 no. HV diesel Generators &belly tanks (GFA c.1,060 m2), 2 no. storage fuel tanks (GFA c.30m2). Data Centre Building C – a single storey data centre building with mezzanine 1st floor level offices (GFA c.18,508m2, building height c.13,658m & structures c.15,137m), made up of 4 no. Data Halls & loading areas with associated 2 no. Dock Levellers &including 20 no. c.14m high flues, &adjacent 2 no. Standby Power Generation Compounds, consisting of 20 no. HV Diesel Generators & belly tanks (GFA c.1,060 m2), 2 no. storage fuel tanks (GFA c.30m2). 3. Upgrading of existing 110 kV Substation to comprise of Compound (c. 8539m2) consisting of 11 kV GIS Switch Room (GFA c.708m2), &4 no. External Transformers (GFA c.550m2), a grid connection, security fence & all assoc works & services. 4. Dev of 1 no. Fire Hydrant Pump Hse (GFA c.129m2) with Sprinkler Tank (c.49m2), 1 no. single storey Security Guard Hse (GFA c.48m2) &2 no. vehicular accesses, internal access rds & 224 no. surface car parking spaces. 5. An upgraded attenuation basin, a proposed ww treatment plant &polishing filter. 6. All assoc site services, with c.2.7m high palisade fence, landscaping, boundary & all assoc site development works above & below ground. An EIAR has been prepared in respect of the proposed dev
Erect an agricultural shed along with all associated site development works
The importation of material to in-fill and re-contour the subject site. Once the importation is complete, the applicant will seed the land in line with Teagasc guidelines and return it to agricultural use. The Operational Phase will see the Site being used as agricultural pastureland. The applicant proposes, subject to planning, to import clean greenfield soil and stone to remediate approximately 2.43ha of the total site. The 2.43ha. is divided into 3 distinct phases - Phase 1 is 0.78ha, Phase 2 is 0.77ha and Phase 3 is 0.88ha. A fill plan has been drawn up for the importation of 18,200tonnes to fill Phase 1, 23,085tonnes to fill Phase 2, and 42,721tonnes to fill Phase 3, equating to a total of 84,006tonnes of soil and stone. Permission is being sought for a 5-year period and will be subject to a waste facility permit
To construct a grain store, concrete aprons & all associated site works in my farmyard
Construction of a bicycle shelter and storage, including ancillary walkers equipment storage/drying room and garden maintenance equipment storage room, all together with associated site works
The proposed development occupies part of the site of (and will supersede) a previously permitted data centre development under Reg. Ref. 20/1285. The proposed development, for which a ten-year permission is sought, consists of the following: Demolition of the existing structures on site (industrial structures and outbuildings) and site clearance works; construction of 3 no. three storey information and communication technology (ICT) facility buildings, each with a gross floor area (GFA) of c. 16,206 sq.m (c. 48,618sq.m GFA in total), and with a parapet height of c. 19.5 metres; each of the 3 no. ICT buildings will accommodate ICT equipment rooms, mechanical equipment rooms, staff welfare facilities, ancillary office space, security rooms, storage, and loading bays; a customer compound, a power trunk building, a transformer compound and a water tank compound area are provided to the north of the ICT facility buildings; the development includes the extension of the existing road and serving the existing industrial park to access the subject site, with gated access points to the proposed ICT facility development to be provided off this roadway; construction of internal road network and circulation areas, footpaths, provision of 124 no. car parking spaces and motorcycle and cycle parking spaces; landscaping and planting, boundary treatments, lighting, security fencing, and all associated site works including underground foul and storm water drainage network, attenuation and percolation areas, and utility cable (including connections to the substation permitted under ABP Ref. 310090-21, resulting in the partial culverting of an existing drainage ditch), on an application site area measuring c. 9.69 hectares. An Environmental Impact Assessment Report (EIAR) has been prepared and will be submitted to the Planning Authority with the planning application
Proposed dwelling, waste water treatment system to EPA standards, garage, new entrance and associated works
The proposed development seeks permission to amend the development permitted under WCC Reg. Ref.: 23/72 and will consist of the following: • Reconfiguration of the internal layout of the 3-no. permitted ICT facility buildings to include ICT equipment rooms, mechanical rooms, switch rooms, electrical equipment rooms, office accommodation, storage and staff facilities at ground and first floor levels; • Amendments to the southern façade on all ICT facility buildings to include alterations to fenestration, extension of permitted louvered façade treatment, and associated alterations; • An increase of c.113 sq.m to the permitted external generator compound of each ICT facility building at ground floor to accommodate additional plant and equipment; • Amendments to plant and equipment layout at roof level and the provision of 1 no. additional roof-mounted emergency landlord generator on each ICT facility building; • Amendments to the permitted water services compound to provide for 1 no. sprinkler tank, 1 no. hydrant tank, 2 no. hydrant water tanks, 2 no. water storage tanks, 6 no. single storey pump rooms (with a gross floor area (GFA) of c. 52 sq.m each) and 1 no. single storey pump room of with a GFA of c. 46 sq.m; • Revisions to permitted site access arrangements including the omission of a permitted security hut and the provision of a revised sally port entrance system with a single storey gatehouse (c. 43 sq.m) and associated revised internal road network; • Relocation of permitted car parking spaces and the provision of 26 no. additional car parking spaces (149 no. spaces in total), Electric Vehicle (EV) car parking and ducting; • The proposed development also includes alterations to the permitted landscaping and planting, fuel filling areas, boundary treatments, security fencing, lighting, SuDS and drainage, and all associated and ancillary site development works. The operation of the development will require an EPA Industrial Emissions Directive (IE) Licence.
Construction of an extension to side and rear of existing garage, creation of a granny flat in part of extension to garage and part of existing garage, creation of boiler room in part of rear extension to garage, removal of 2 containers, new outdoor patio area, new covered canopy area to rear of dwelling, converting rear window in existing dwelling to door and associate works
Dwelling,garage, upgrade to existing entrance, bored well, effluent disposal systems to current EPA standards and all associated site works
Of 1) garden room and 2) garden storage building
Detached bungalow with detached garage together with waste water treatment system to current EPA standards, on site bored well, new vehicular entrance onto main road and ancillary works
(1) revised dwelling position, (2) revised well and septic tank position and (3) revised entrance position. Permission is sought to revise site boundaries as a change to that permitted under 014626 and all associated site and ancillary works
Construction of a slatted cattle house/store, cattle handling facilities, farm roadway and farmyard entrance, together with associated concrete yards and site works
Erect a first floor dormer extension with alterations and revisions to the elevations of the existing dwelling along with all associated site development works
Amendments to roof design of previously approved house (Planning Ref No. 21/257) and for the inclusion of 2 No. Velux type windows on side elevation over kitchen area
Rear/side extension to existing main cottage. Permission for new extension to the rear of main cottage, which will create a link connection, to existing outhouse buildings, conversion of existing outhouse building to home office/workshop and conversion of existing outhouse building to self-contained apartment/granny flat, with double bathroom extension to the rear-south elevation, one for the studio, one for self-contained apartment/granny flat. Associated site works and some internal alterations
Erect a dwelling and garage with services along with all associated site development works
Alterations and additions to an existing single storey detached dwelling, comprising the construction of a new single storey utility room extension to the rear, the construction of a new single storey bedroom extension to the front elevation, and the conversion of an existing detached garage area into home office, together with the construction of a new single storey domestic garage to the side of the existing dwelling, including all ancillary site works. Retention permission is also being sought for the conversion of an existing detached single storey garage structure into ancillary games/garden room at the same address
Proposed dwelling, waste water treatment system to EPA standards, garage, entrance and associated works
Dwelling, wastewater treatment system to EPA standards, entrance incorporating revision to existing entrance and associated works
Proposed development. The proposed development includes an amendment to the development permitted under Reg. Ref. 21/1080, The proposed development will consist of the following to facilitate the above. Demolition of the existing structures on the western part of the site that comprises 4 no. industrial commercial buildings, an associated hut / outbuilding, a gas enclosure, and a tank with bund wall. The removal of the remains of a previously demolished building, areas of hard standing, and existing surface treatments. The relocation of the Energy Centre 1 to the western part of the site, which will supersede the previously permitted 110kV GIS substation compound at that location under ABP Ref: VA27.309252. The proposed development will provide for a revised energy centre design, to include the provision of 8 no. gas turbines (with associated flues of 25.15m in height), 4 no. black start emergency generators and associated transformers, 2 no. single storey fuel oil pump rooms with a gross floor area (GFA) of 90.17sq.m, a single storey air compressor building with a GFA of 88.9sq.m, 4 no. fuel tanks, 2 no. MCC control rooms with a GFA of 44.17sq.m, 3 no. fire water tanks, a single storey welfare, storage, and pump room building with a combined GFA of 160.97 sq.m, a two storey MV /LV building with a GFA of 655.54sq.m, 8 no. 11kV/ 33kV step-up transformers in the north of the site, water treatment equipment, and a security hut, all within a fenced compound. The proposed development includes landscaping and planting, boundary treatments, lighting, security fencing, car parking, and all site works including underground foul and storm water drainage network (including on-site wastewater treatment system), and utility cables, along with all associated and ancillary works. An EPA- Industrial Emissions Directive (IED) licence will be applied for to facilitate the operation of the proposed development