The development shall consist of the construction of two single storey units (Unit 23 and 27) for Industrial and/ or Warehouse use with associated ancillary two storey offices and car parking, comprising a total gross floor area of 10,718.84 m2. Unit 23 shall measure 4,485.45 m2 complete with 50 carpark spaces and Unit 27 shall measure 6,215.89 m2 complete with 71 carpark spaces. The development will also include an ESB sub-station to Unit 27, measuring 17.5 m2, service yards, signage to the proposed units, the extension of Birch drive to the east, service access roads and all associated landscaping and ancillary site works for undeground duct work, drainage and utility services, on a site area of 2.40 hectares.
Planning precedent report
Search a place or planning reference, choose the development type, then preview the report before generating the full PDF.Planning precedent report
Dublin Airport Logistics Park, St Margaret's Road, St Margaret's, Co.
One-off house / within 5 km where a location match is available
Executive snapshot
Local planning pattern
10% of nearby decided applications were refused. The preview found 2,158 nearby planning records within 5 km where a location match is available.
- Matched source
- FW20A/0209
- Project type
- One-off house
- Coverage
- 5 km radius
Open preview
Top refusal reasons nearby
Open preview
Nearest similar decisions
The introduction of ancillary accomodation and office space at second floor (including partial mezzanine area) and alterations to the existing fenestration to the south and west elevations of approved planning ref (FW20A/0209).
The development consists of the material change of use from warehouse space to (a) a single storey climate controlled room (2,493m2), clean room (60m2) and office (42m2) to the warehouse area, cold store rooms to the mezzanine undercroft (187m2) comprising total gross floor area of 2,782m2, (b) two large tanks, one containing water servicing the sprinkler system (8.462m high/9.3m diameter) and one containing liquid nitrogen (8.15m high/3.57m diameter) and associated sprinkler pump room (35m2) to the rear service yard area and (c) all associated site works. AI Received 24th September 2025 Significant Additional information Received 14/10/2025
The construction of a single storey unit for industrial and/or warehou
The construction of a standard two room electrical substation to the r
Installation of new railings to west elevation, north elevation and no
Source match
Matched from public planning record FW20A/0209The full report adds the full list of similar grants and refusals, source quotes, document links, and a shareable PDF summary.
Included in full report
Policy and design risk
Included in full report
Source document extracts
Included in full report
Comparable decision table