Showing 1-50 of 32,676 public recordsTemporary retention permission and temporary permission for development on this c. 1.29 ha site. This site is referred to as 'Site 1' for the purposes of the planning application. The development for which temporary retention permission is sought comprises the use of the site as a storage facility, including: unstacked storage containers used for self-storage purposes (max. height c. 2.9m); stacked storage containers used for rent/sale off-site (max. height c. 11.6m); a depot storage shed (c. 202 sq m); an office (c. 56 sq m); vehicular access entrance to the site and associated security gates; internal access gates; 2.4m high fencing located within the site and along site boundaries; and 2.5m high block wall located along western site boundary. The development for which temporary permission is sought comprises: a 2.4m high fence, located adjacent to the existing vehicular entrance; and landscape planting. Temporary retention permission and temporary permission is sought for a duration of three years. AI Received 23/09/2025
1 Rentention of stacked containers on part of the premises which were temporarily approved under reg ref FW17A/0198. 2.Rentention of depot storage shed of 157.85 sqm2 used in container storage operations. 3. Retention of new extended storage area of 0.297 ha for storage of single non stacked containers. 4. New 10 year temporary permission for entire premises of 1.09 ha at site D&E Gateway, Rosemount Business Park, Blanchardstown Dublin 11. Add Info received 26th February 2021.
Temporary retention permission and temporary permission for development on this c. 2.61 ha site at Area C and D Gateway,. This site is referred to as 'Site 2' for the purposes of the planning application. The development for which temporary retention permission is sought comprises the use of the site as a storage container facility, including: unstacked storage containers used for self-storage purposes (max. height c. 2.9m); vehicular access entrance to the site and associated security gates; 2.4m high fencing located within the site and along site boundaries; and signage. The development for which temporary permission is sought comprises: stacked storage containers used for rent/sale off-site (max. height c. 5.8m), setback c. 15.5m from the north-eastern site boundary (Rosemount Park Drive); a segregated internal access route, with associated fencing and access gates; 2.4m high fencing located within the site and along site boundaries; 2.5m high block wall located along western site boundary; and landscape planting. Temporary retention permission and temporary permission is sought for a duration of five years. AI Received 23/09/2025 Significant additional information received 29/09/2025
Permission for retention of extension of 2.47ha to their self-storage container park at site D & E Gateway, Rosemount Business Park, Blanchardstown, Dublin 11. Access is via the existing premises and from a new proposed vehicular access from Rosemount Park Drive for which permission is also being sought. Works carried out include new 2.4m high palisade fencing along the southern and north east site boundaries and a 2.5m high screen wall to the western boundary. A ten year temporary permission is sought for both the existing and extended premises. AI Rcvd 5/12/23
Planning permission to ammend Reg Ref. FW17A/0190
Retention of an internal two-tier mezzanine floor (installed 2004) for storage of materials ancillary to the existing warehouse operations. The space is used exclusively for storage.
Permission for change of use of existing meat processing plan to new use as a car showroom, car storage facility, external car lift, workshop, minor amendments to the external elevations, new signage, onsite motor factors, modular freestanding shared working space building together with all associated ancillary and incidental site works. AI received 02/02/23
Retention of a single storey loading dock and stairwell door to north west elevation, single storey plant room to south east elevation and minor associated site works.
Permission for construction of building to replace recently demolished fire damaged building for its previously permitted use as a car showroom, car storage facility, external car lift, workshop, signage, onsite motor factors, connection to necessary services together with all associated ancillary and incidental site works.
Retention of an internal two-tier mezzanine floor (installed 2017) for storage of materials ancillary to the existing warehouse operations. The space is used exclusively for storage.
The development will consist of: (a) The intake & temporary indoor storage of Batteries (EWC Code 16 06 01), in leak-proof containers, and dispatch as received for off-site recovery by others; (b) the intake of wastes from end-of-life vehicles from different means of transport (including off-road machinery) and wastes from dismantling of end-of-life vehicles and vehicle maintenance (except 13, 14, 16 06 and 16 08) and specifically Ferrous Metals EWC Code 16 01 17 and EWC Code 16 01 18; (c) The intake of wastes from electrical and electronic equipment (EWC Code Heading 16 02..), specifically listed under EWC Code 16 02 16, namely components removed from discarded equipment other than those mentioned in 16 02 15; and including batteries listed under EWC Codes as follows: 16 06 01* lead batteries; 16 06 02* Ni-Cd batteries; 16 06 03* mercury-containing batteries; 16 06 04 alkaline batteries (except 16 06 03); (d) Permission to apply a concrete surface to approx. 398 m2 of site area to the northeast of, and adjoining, Unit 6D Rosemount Park Drive, Rosemount Business Park, Ballycoolin, Dublin 15 to facilitate installation of a vehicular weighbridge and parking for transport vehicles, and (e) Provide a vehicular entrance from Rosemount Park Drive to this north east area of the site, (f) and Replace Existing Palisade Fencing in front of the building line with Metal Rail fencing of similar height.
1) Permission for retention of an existing logistics depot with associated services and 2) Permission for the establishment of an Upper Tier site under COMAH (Control of Major Accidents and Hazards) Directive and for the expansion of the existing logistics depot to include: a) the demolition and removal of existing structures on site; b) the construction of the following: i) the provision of 53 no. parking spaces for trucks/HCV's, ii) an office building with associated staff facilities including kitchen and W/C; iii) a maintenance and wash bay shed for servicing equipment and commercial vehicles; iv) a boiler room and steam cleaning room; v) a fuel island and associated tanks for on-site fuelling of commercial vehicles vi) tank container storage area for the temporary storage of containers for onward transport in compliance with the COMAH directive and c) all associated site development works including 33 no. car parking spaces, landscaping, drainage, wastewater treatment facility and boundary treatment facility and boundary treatments. AI Received 20 March 2024 CAI Received 06/08/2024
Retention is sought for a previously granted Temporary Retention Permission ref FW19A/0014. The development consists of parking commercial vehicles containers, plant machinery and mobile office & storage units. AI Rcvd 27/05/2025 SAI Rcvd 03/06/2025
The proposed development consists of the following: • The change of use of the existing vacant two-storey office building (GFA 1,652 sq.m) to a recreational/sports facility, including gym use (Class 11); • Allocating 99 no. car parking spaces within the existing car park, including 3 no. accessible spaces, to serve the sports facility; • Provision of secure bicycle stores providing a total of 66 no. cycle parking spaces; • Minor alterations to the building elevations, including the installation of 2 no. tenant signs; and • All associated and ancillary site development works.
Provision of extension (148.9msq) to existing warehouse.
Planning permission for the constructon of
Planning permission for the installation of 2no. pair of automatic entrance gates, 1 no. pedestrian gate and 2.4 metres high fencing (circa 80 metres total length) to entrance area to the Site (A & B). Also we are applying for Retention Permission for installation of external ground level refrigeration plant equipment at the Southern Elevation of Unit A, ancillary to the Chiller Rooms within the Unit.
The development will consist of change of use from warehouse to laboratory and office use over the ground and first floor level to include for internal alterations, extension of floor areas, and provision of a mezzanine floor. AI received 15/12/22 SAI received 03/01/23
Temporary development (5 year duration) consisting of the following; (a) hardstanding external car park for c.45 no. cars with vehicular access onto the Public Road (b) an external car wash bay (c) a steel clad commercial unit (c.287 sq.m.) for both internal parking/recovery and car valeting (d) a chemical WC cubicle for staff (e) advertising signage as erected (f) external lighting column and CCTV cameras and (g) connection to (e) advertising signage as erected (f) external lighting column and CCTV cameras and (g) connection to surface water network and all other associated siteworks.
The development will consist of the installation of a replacement asphalt plant (c. 30 metres high) with a stack height of c. 30 metres, aggregate storage bins (c. 4m high) and associated conveyor systems, 3 no. bitumen storage tanks (c. 14m high), recycled asphalt pavement (RAP) system, control cabin (20m2), dust collection system improvements to vehicular circulation to/from the plant, and all ancillary works within an application area of c. 0.67 Ha. The proposed development will replace the existing asphalt plant which will be removed. The application site forms part of EPA IPC Licence Ref: P0081-02 for Breedon Materials Ltd. AI received 23/05/2025
Permission is sought for a new play area and low fence in the 3 existing car parking spaces to the front, and also an increase in childcare places from 40 to 72 places at any one time, at Little Harvard Creche & Montessori.
Permission is sought for an increase in childcare places from 40 to 72 places. AI Rcvd 07/03/2025
The development will consist of the retention of the use of the external area of the existing Waste Plastics Recycling Facility at this site for product and materials storage and pre-processing activity and all associated ancillary development, including staff and visitor car parking. The site is licensed under Waste Facility Permit WFP-FG-08-0002-05.
Construction of new loading bay to front of existing industrial unit, and associated site works.
Planning permission for construction of new loading bay to rear of existing industrial unit and associated site works. AI Rcvd 17/07/2024
The development will consist of a single storey extension to the side of the building for dock-leveller delivery provisions (110 sq.m.) and a single storey warehouse managers offices (28.2 sq.m.), the provision of additional warehouse access doors and personnel doors, all with associated minimal siteworks and elevation alterations.
Breedon Materials Ltd., trading as Breedon Ireland intend to apply for permission for development at Rosemount Business Park, Ballycoolin Road, Dublin 11. The development will consist of the installation of a replacement concrete plant; aggregate storage bins (c. 15.3 m high), surface and underground conveyor system; control cabin (32 sq.m); 4 no. cement silos (c. 13.3 m high); concrete truck washout bays (c. 240 sq.m) (closed system); demolition of the existing garage (c. 105 sq.m) and office (c. 40 sq.m); and all ancillary works within an application area of c.0.91 Ha. The proposed development will replace the existing concrete plant which will be removed. AI received 21/02/2025
The development will consist of the following:
The Applicationfor permission consists
The application for retention consists of construction of a new 500KVA substation (gfa of 30.1 sqm & max height of 3.2 m) and back-up generator. The development will also include amendement to permission Ref. FW17A/0167 and permission Ref. FW18A/0114 to include the works subject to retention.
Permission for a pallet handling facility. The development will consist of; (A) The inclusion of a Kiln structure for drying wooden pallets, 100m2 x 6m high, plus removal of an existing external wash bay - all positioned to the rear of the existing warehouse on site. (B) Removal of a part build unauthorised shed, 500m2, 6.9m high, and planning permission for relocation of part of this structure, 365m2, 6.9m high and completion as a dry pallet store building. (C) Relocation of existing ancillary carpark spaces to the front (east) of the existing building at the site entrance along with other associated site plan adjustments & completions such as widening of site access from 6m to 10m including associated kerb & footpath adjustments, surfacing the existing yard with concrete over the existing compacted stone and placing associated surface water drainage including surface water attenuation. (D) Removal of existing shed measuring, 110m2, 5.6m high, currently centrally located in yard. Using the yard as a pallet store for the pallet repair and dispatch business by providing 950m2 external storage at three locations on site, including associated ancillary HGV parking area 315m2. Add Info received 27th January 2021. Add Info deemed Significant 2nd February 2021. Revised Public Notices received 5th February 2021.
Permission for a HGV Parking and Tanker Washing Facility, the proposed development will consist of the following: (1) Facility building consisting of: (a) 3 no. Tanker Wash Bays for internal washdown of HGV Tankers (488m², 10.40m high). (b) Associated plant room with pumps and water treatment (241m², 10.57m high). (c) Workshop for maintenance and repair of HGV's (329m², 10.57m high). (d) Attached ancillary single storey Office/Staff facility accommodation (147m², 5.40m high). (2) Secure parking for 34 no. HGV's over a net area of 2,142m² with access and ancillary marshalling areas. (3) Ancillary car parking for 12 no. vehicles and 8 no. bicycle parking spaces. (4) ESB Sub-station 9.0m², 3.0m high located at previously granted cul de sac access road. This development will also include site fencing, HGV and pedestrian gate, boundary treatment - landscaping, paving, external lighting, provision of services and utilities including foul sewer and surface water management facilities. The subject site will be accessed from an existing cul de sac road connected to the existing roundabout on Cappagh Road as previously granted planning permission under FCC file reg. ref. FW19A/0231. AI received 18/02/2022
Planning Permission is sought for Alterations to an existing granted planning application Reg. Ref. FW21A/0111 for a proposed Tanker Washing Facility with ancillary Office and Staff Facilities at Cappagh Road, Cappagh Corporate Park, Ballycoolin, Dublin 11, Co. Dublin. The subject alterations for which Planning Alterations is sought for are as follows: 1.A. Reconfiguration of the floor plan areas and inclusion of a pump house, 48m2, 4.15m high, to rear (Northern) yard. Totalling 329m² additional floor area with a total area increase from 1,214m² (previously permitted) to 1,543m² (proposed). 2.A. Elevations alterations associated with above floor area adjustments; B. Proposed 2 No. non-illuminated company logo signage, 3.80m x 2m each, total area of 15.20m2 located 9m above ground floor level on the eastern & western building elevations. 3.Site plan alterations as follows: A. Inclusion of Truck Wash bays to the western boundary; B. Reduction in HGV parking spaces from permitted 34No to 10No HGV parking spaces to the eastern boundary; C. Provision of 2No. Water Tanks 5.00m diameter, 5m high, effective capacity = 98m3 each, to rear (Northern) yard, which will serve the facility building; D. Provision of additional 4No. covered bicycle parking spaces totalling 12No. covered bicycle parking spaces provided. E. Associated change of external surface finishes, landscape and drainage adjustments due to the inclusion of the alterations above; 4.A. Provision of 264No. Solar PV Panel modules with overall area of 570m² to the facility roof only. All other details will remain as per the granted application reg. ref. FW21A/0111.
Retention of revisions to the development as granted permission under FW20A/0216 - the revisions include 1. Extending the Ground floor warehouse area by 465 sq. m under a permitted covered canopy with associated elevation changes 2. Omission of a planned welfare facilities building and all associated site works.
Construction of a warehouse distribution centre consisting of a single storey warehouse and canopy, associated office located over two floors, welfare facilities building, car and HGV parking spaces, marshalling yard, signage, site fencing, gates, lighting and all associated site works and ancillary services including the construction of two new site entrances. AI received 07/05/21
The application for permission consists of amendments to permission Reg. Ref. FW17A/0167 as amended by permission Reg. Refs. FW18A/0114, and FW24A/0246E accounting for various amendments to the permitted 3 no. data centres, associated infrastructure and associated works. The proposed modifications will comprise the following: • Revised layout for southwest corner of the site to provide for a Battery Energy Storage System (BESS) with raised platform and screening, and modifications to the permitted concrete surface and landscaping to allow for same; • 500mm increase in the building height of the permitted MV2 building. • Modification of stair access to the permitted fuel & Urea tanks by way of addition of 2 No. steel stair towers; • Addition of plant housing between the CSB building and fuel tanks of c. 15 sq m and height of c. 3.7m; • Change in height of flue sampling platforms at each of the 3 No. flue groups by 800mm; and • All associated works ancillary to the modifications. The application relates to a development for the purposes of an activity requiring an industrial emissions licence and EPA-Industrial Emissions Directive (IE) licence (EPA Reg No. P1210-01) has been applied for in relation to the activity at the development site.
The application for planning permission consists of modifications to permission Ref. FW17A/0167 (for demolition of existing warehouse and construction of 3 no. data centres and associated works) and permission Ref. FW18A/0114 (Amendments to the permitted 3 no. data centres and associated works). The proposed modifications will comprise the following: Revised layout of Plant Yard No. 1 to provide a new gas pressure reduction station (GPRS), revised Energy Centre, modifications to permitted flue design, and alteration of HV Building to MV building and revised design; Revised layout of Plant Yard No. 2 to provide revised Energy Centre, modifications to permitted flue design, fuel storage tanks, and combined services building; Revised layout of Plant Yard No. 3 to provide revised Energy Centre, modifications to permitted flue design, and alteration of HV Building to MV building and revised design, new battery energy storage system (BESS); Modifications to internal access and landscape areas to accommodate redesigned Plant Yards; Ancillary infrastructure including revised sprinkler tank and pumphouse location; Minor modifications to rear loading of Buildings No. 1, 2 and 3; and All associated works ancillary to the modifications. The proposed modifications will also include a temporary energy generation compound for a period of c. 1.5 year. The temporary modifications include: Installation of 4 no. gas powered generators and 4 no. bio diesel (HVO) generators (including biodiesel storage) used in standby application; Each generator will include a 12 m tall flue stack; 2 no. Battery Storage area and a Battery inverter station; Installation of 6 no. containerised switchgear rooms and 6 no. Transformers; and ancillary equipment including fuel interceptor. Following the temporary period, Data Centre building No. 2 will be developed in accordance with the layout and design as permitted by FW18A/0114 including the modifications proposed in this application. The temporary works will be removed once Energy Centre No. 1 and 2 have been commissioned. The remainder of the development is to be carried out in accordance with parent permission Reg Ref. FW17A/0167, Amendment permission FW18A/0114, and any subsequent amendments permitted by this application for planning permission.
Permission for provision of an additional single storey modular switchgear building within the substation compound with a gross floor area of c. 46 sq.m.; Provision of 2 no. additional electrical transformers along with associated firewalls and lightning protection masts; Extension of the existing substation compound to accommodate the new transformers and switchgear building; Realignment of the existing access road to the south to enable the extension of the substation compound; and All associated and ancillary works, including boundary treatments, access arrangements, and services. The site takes in part of an existing substation compound permitted under Reg. Ref. FW16A/0159 as modified by Reg. REf. FW17a/0103 and an adjoining private access road. The site is bound to the west by an existing data storage facility, and to the northeast and southeast by exiting estate roads.
The development will consist of the following A) Replacement of existing external branding signage, and B) New external branding signage. This will include the replacement of existing wall mounted signage, the replacement of existing totem and monolith signage along the site boundary, and the erection of branded flags on existing flag poles.
The development will consist of modifications to permission Ref. FW17A/0167 (for demolition of existing warehouse and construction of 3 no. data centres and associated works) and permission Ref. FW18A/0114 (Amendments to the permitted 3 no. data centres and associated works). the proposed modifications will relate to the first phase of the permitted development which encompasses Building No. 1, Energy Centre No. 1, the main site entrance, internal access roads, ancillary infrastructure, 35 no. car parking spaces and 24 no. bicycle spaces. The proposes modifications will comprise the following; Revised internal layout of building No. 1 with associated elevational changes including but not limited to material alterations, alteration of door locations, alteration of louver locations, alteration to the loading bay area and addition of canopies to the front and rear of the building; The provision of Solar PV Panels to the roof of the administration building; Additional roof penetrations; Alteration to the size, orientation and design of the seurity/guard house building no. 1; Alteration to the car park, entrance and access roads within the site, relocation of 4 no. motorbike parking spaces and addition of 1 no. additional space (total 5), provision of 4 no. EV charging points (with ducting provided for a further 14 no. future charging points). Alteration to the location and design of the gas metering skid, pump house and sprinkler water tank; Modification to the landscaping, perimeter fencing and entrance gates; Modification to the location and design of the GNI compound and its separate vehicle entrance along the southern boundary; and All associated site development works, landscape works and service provision. The gross floor area of Building No. 1 decreased to 12,153.63 spm and the total gross floor area of the proposed development revised to 39.802.87 sqm. The proposed modifications to the first phase of the development will also include alteration to the energy centre for building no. 1 for a temporary period of c. 3.5 years. The temporary modifications within the generator yard include; Installation of 4 no. gas powered generators and 4 no. bio diesel (HVO) generators (including biodiesel storage) used in standby applications; Each generator will include a 12m tall flue stack; 2 no. Battery Storage area and a Battery inverter station; and Installation of 6 no. containerised switch gear rooms and 8 no. transformers; Installation of a n ESB substation(Max 500K Va) for a temporary period of c. 3.5 years is also proposed to the south of the generator yard. the temporary modifications will replace the permitted layout for the temporary period. Following the temporary period, the energy centre including the generator yard will return to the layout and design as permitted by FW18A/0114. The temporary works will be removed once Building 2 & 3 have been commissioned. The remainder of the development to be carried out in accordance with parent permission Reg. Ref. FW17A/0167 and Amendment permission FW18A/0114.
The development will consist of the installation of a substation building comprising of an ESB supply room and 1 no. switch room (c. 46 sq.m) within a planning application area of c 0.0046 Ha.
The proposed development will consist of (i) Change of use of existing cafe to new use as Window Shading Training Academy (ii) Minor amendments to the internal layout (iii) New cladding to external elevations with new signage (iv) and all associated ancillary and site works. AI Rcvd 07/11/2024
Planning permission for the construction of a national velodrome and badminton arena over a footprint of 8,100 sqm comprising 250m cycle track with 12 no. badminton courts within, internal bicycle store area, changing rooms, medical and emergency rooms, areas for offices, administration and meetings, timing, event and training control, training and event preparation, strength and conditioning, circulation and storage, stairs and lifts, and proposed service area to the rear. Provision of circa 1,000 no. permanent spectator seats, with provision to accommodate other occasional sporting events within the track with scope for a further temporary 2.500 seats for non cycling and badminton sporting events. The proposed structure is 16.4 m in height to the continuous parapet, the centre of the roof proposed is 19.6 m in height at the structure tallest point, is 120 m in length, and is 90 m at its widest part. the exterior of the structure will be of profiled metal rainscreen cladding placed upon a plinth of vertical profiled louvres and curtain wall glazing, with an aluminium standing seam roof. External works include the creation of a surrounding plaza area including "cycling walk of fame", reprofiling of surrounding land utilising spoil from excavation for the proposed development to include and extensive soft landscaped area including additional tree planting, enhancement of biodiversity, and allowance for potential future cyclo-cross course to the north/BMX track to the east, sustainable urban drainage scheme, network of pedestrian routes, allowance for future provision of light rapid transit system in close proximity to the proposed structure, provision of 301 no. car parking spaces including 16 no. accessibility spaces and 30 no. EV charging spaces, 120 bicycle parking spaces half of which are covered, provision of power points for e0bikes, 12 no. dedicated coach park spaces and drop off point, and all associated works. AI Received 16/11/2022 SAI Received 22/11/2022
New entrance area at the National Indoor Arena; alterations to existing vehicular access, provision of some 200 no car parking spaces including disabled spaces and 5 no. EV charging spaces; provison of 200 bicycle spaces, and enhanced landscaping at the National Indoor Arena, National Sports Campus, Blanchardstown, Dublin 15.
Permission for the removal of Planning Condition 10 (a) (i) of Planning Permission Ref: FW22A/0166 for the national velodrome and badminton arena to permit a 5.21m landscaped earth mound in excess of the conditioned 2.5m mound. The permitted development is located at the National Sports Campus, Snugborough Road, Blanchardstown, Dublin 15.
The application relates to development located on a site that will comprise or will be for the purposes of an activity requiring an Industrial Emissions Licence. The application for planning permission relates to an existing and permitted [Permission Ref. FW17A/0167 (for demolition of existing warehouse and construction of 3 no. data centres and associated works), permission Ref. FW18A/0114 (Amendments to the permitted 3 no. data centres and associated works), permission FW24A/0246E (Amendments to permitted plant yards, energy centres, loading areas and ancillary works)] data centre development. Permission is sought for construction of a data centre building [DUB01b] which will result in the amalgamation of the permitted DC2 and DC3 buildings [FW17A/0167 & FW18A/0114] and include the provision of the permitted Energy Centre EC3 [FW24A/0246E]. The data centre building will include data halls, offices, staff areas, storage areas, plant areas, roof plant, solar PV at roof top level and green roof above office space. The building will have a maximum parapet height of 15.07m. The total floor area of the proposed DUB01b is c.22,295 m2. EC3 will have a gfa of c. 1433m2, parapet height of 12.67m and flues height of 28.0m. Permission is also sought for a 10MVA/38kV substation with a maximum height of c.4.5m and gfa of 173m2, substation maintenance access, heat recovery infrastructure, carpark area with c. 57no. carspaces including 3no. accessible car spaces, and 24 no. EV car parking spaces with charge points. A total of 48no. covered bicycle spaces are also proposed. Permission is also sought for all landscaping (including biodiversity area), drainage, waste storage area, internal and external accessways. The development will be completed within five years of the date of the permission being sought.
Permission to relocate the substation and meter room to an outdoor service yard located at the rear and north of the permitted National Velodrome and Badminton Arena building (previously approved under planning permission ref: FW22A/0166). The proposed substation and meter room will be a single-storey structure recessed into the landscaped earthen area. To accommodate this development, there will be a minor modification to the previously approved concrete retaining wall alignment, which now wraps around the proposed development.
Construction of a high bay warehouse/storage facility to the north of 7B for use as 'Goods Outward' building, all ancillary to the use of the existing buildings and activities on site.
The application for retention consists of modifications to the permitted entry area and guardhouse (gfa45.67 sqm & max height 4.275m) in relation to orientation and design. Other minor modifications to car parking and landscaping are also included. The development will also include amendment to permission Ref. FW17A/0167 and permission Ref. FW18A/0114 to include the works subject to retention. AI rcvd 05/04/2024
A single storey temporary modular structure extension (133 msq) to the existing Sport HQ Building (Previously the Marine Institute Building) for a period not greater than 10 years. The works will comprise;- open plan/cellular office and meeting spaces (114 m sq); an interlink corridor (19msq); and all associated site development, hard landscaping, and excavation works above and below ground.